ITAC Assessment: SU0559
ITAC logo
ITAC Assessment: SU0559
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Fabric
NAICS 313240: Knit Fabric Mills
SIC 2258: Lace and Warp Knit Fabric Mills
Sales Range $500
k
to 1
M
# of Employees 61
Plant Area 79,000
ft2
Annual Production 1,300,000
lb
Production Hrs. Annual 6,240
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $153,040 1,545,787
kWh
Electricity Demand $33,613 2,668
kW-mo/yr
Electricity Fees $22,432 -
LPG $5,314 303
MMBtu
Fuel Oil #6 $36,746 1,485
MMBtu
TOTAL YEARLY COSTS $251,146
RECOMMENDED SAVINGS* $237,553 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings LPG Savings Fuel Oil #6 Savings One-time Revenue or Avoided Cost Savings
01 4.821: Pay bills on time to avoid late fees $1,057 - - - - - $1,057
02 2.4322: Use or replace with energy efficient substitutes $519 $27 $757
7,650
kWh
$529
-
kW-mo/yr
$(-97.2)
-
MMBtu
$(-670.4)
-
MMBtu
-
03 2.8121: Apply for tax-free status for energy purchases $498 $27 - - - - $498
04 2.7447: Install vinyl strip / high speed / air curtain doors $662 $307 - - $84
-
MMBtu
$578
-
MMBtu
-
05 2.2136: Install / repair insulation on steam lines $5,926 $3,523 - - $749
-
MMBtu
$5,177
-
MMBtu
-
06 2.7232: Replace existing hvac unit with high efficiency model $3,988 $4,574 $3,988
40,278
kWh
- - - -
07 2.7212: Install or upgrade insulation on hvac distribution systems $37,111 $44,118 - - $4,689
-
MMBtu
$32,422
-
MMBtu
-
08 2.6211: Conserve energy by efficient use of vending machines $577 $888 $577
5,825
kWh
- - - -
09 2.7234: Use heat pump for space conditioning $175,181 $421,500 $(-55,085.2)
(-556,416)
kWh
- - $230,266
-
MMBtu
-
10 2.8227: Adjust / maintain fork lift trucks for most efficient operation $12,034 $165,150 $(-4,061.8)
(-41,028)
kWh
- $16,095
-
MMBtu
- -
TOTAL RECOMMENDED $237,553 $640,113 $(-53,825.1)
(-543,690)
kWh
$529
-
kW-mo/yr
$21,520
-
MMBtu
$267,773
-
MMBtu
$1,555
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings LPG Savings Fuel Oil #6 Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs