| Assessment Year | 2024 |
|---|---|
| Principal Product | Biologics Drug Substance |
| NAICS | 325414: Biological Product (except Diagnostic) Manufacturing |
| SIC | 2834: Pharmaceutical Preparations |
| Sales Range | $100 M to 500M |
| # of Employees | 479 |
| Plant Area |
4,390,446
ft2
|
| Annual Production | 40
units
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,469,891 | 32,049,008 |
kWh
|
$0.046 |
| Electricity Demand | $283,182 | 65,326 |
kW-mo/yr
|
$4.33 |
| Electricity Fees | $275,691 | - |
|
- |
| Natural Gas | $706,645 | 406,377 |
MMBtu
|
$1.74 |
| TOTAL YEARLY COSTS | $2,735,409 | |||
| RECOMMENDED SAVINGS* | $116,364 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $104,040 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7122: Disconnect ballasts | $535 | - |
$474
10,302
kWh
|
$61
-
kW-mo/yr
|
- | - | |
| 02 | 2.7224: Reduce space conditioning during non-working hours | $371 | - | - | - | - |
$371
-
MMBtu
|
|
| 03 | 2.4239: Eliminate or reduce compressed air usage | $11,772 | - |
$11,772
254,829
kWh
|
- | - | - | |
| 04 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $23,444 | $5,758 |
$23,444
509,659
kWh
|
- | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $585 | $20,063 |
$505
10,968
kWh
|
$65
-
kW-mo/yr
|
$15 | - | |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $4,149 | $15,000 |
$4,149
90,187
kWh
|
- | - | - | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,582 | - |
$2,582
56,122
kWh
|
- | - | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $669 | $1,050 |
$592
12,877
kWh
|
$76
-
kW-mo/yr
|
- | - | |
| 09 | 2.9114: Use solar heat to make electricty | $9,473 | $27,789 |
$9,473
57,994
kWh
|
- | - | - | |
| 10 | 2.6211: Conserve energy by efficient use of vending machines | $181 | - |
$181
3,942
kWh
|
- | - | - | |
| 11 | 2.9114: Use solar heat to make electricty | $62,603 | $652,137 |
$62,603
1,360,962
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $116,364 | $721,797 |
$115,775
2,367,842
kWh
|
$203
-
kW-mo/yr
|
$15 |
$371
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $104,040 | $721,797 |
$103,822
2,109,071
kWh
|
$203
-
kW-mo/yr
|
$15 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs