Assessment Year | 2024 |
---|---|
Principal Product | Contract Metal Fabricator |
NAICS | 332322: Sheet Metal Work Manufacturing |
SIC | 3444: Sheet Metal Work |
Sales Range | $50 M to 100M |
# of Employees | 110 |
Plant Area |
135,000
ft2
|
Annual Production | 2,600,000
units
|
Production Hrs. Annual | 6,400
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $193,521 | 1,961,131 |
kWh
|
$0.099 | |
Electricity Demand | $76,975 | 7,086 |
kW-mo/yr
|
$10.86 | |
Natural Gas | $62,547 | 12,801 |
MMBtu
|
$4.89 | |
Waste Disposal Costs | |||||
Water Usage | $3,537 | 332,000 |
Tgal
|
$0.011 | |
Solid Waste (non-haz) | $29,215 | 100,000 |
lb
|
$0.29 | |
TOTAL YEARLY COSTS | $365,795 | ||||
RECOMMENDED SAVINGS* | $61,592 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $669 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $9,727 | $45 | - | - | - | $9,727 | |
02 | 2.8121: Apply for tax-free status for energy purchases | $1,784 | $45 | - | - | - | $1,784 | |
03 | 2.7122: Disconnect ballasts | $104 | - |
$81
815
kWh
|
$23
-
kW-mo/yr
|
- | - | |
04 | 2.4239: Eliminate or reduce compressed air usage | $576 | - |
$576
5,818
kWh
|
- | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $159 | - |
$159
1,606
kWh
|
- | - | - | |
06 | 2.4322: Use or replace with energy efficient substitutes | $1,870 | $113 |
$1,337
13,500
kWh
|
$815
-
kW-mo/yr
|
$(-281.3)
-
MMBtu
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $669 | $83 |
$163
1,642
kWh
|
$25
-
kW-mo/yr
|
- | $482 | |
08 | 2.4221: Install compressor air intakes in coolest locations | $1,364 | $413 |
$1,364
13,775
kWh
|
- | - | - | |
09 | 2.9114: Use solar heat to make electricty | $27,713 | $29,395 |
$27,713
279,930
kWh
|
- | - | - | |
10 | 2.6211: Conserve energy by efficient use of vending machines | $924 | $1,011 |
$924
9,330
kWh
|
- | - | - | |
11 | 2.8227: Adjust / maintain fork lift trucks for most efficient operation | $16,546 | $21,000 |
$(-6,063.8)
(-61,250)
kWh
|
- | - | $22,610 | |
12 | 2.7135: Install occupancy sensors | $111 | $185 |
$111
1,121
kWh
|
- | - | - | |
13 | 2.2437: Recover waste heat from equipment | $46 | $198 | - | - |
$46
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $61,592 | $52,487 |
$26,363
266,288
kWh
|
$862
-
kW-mo/yr
|
$(-235.4)
-
MMBtu
|
$34,602 | ||
TOTAL IMPLEMENTED | $669 | $83 |
$163
1,642
kWh
|
$25
-
kW-mo/yr
|
- | $482 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs