Assessment Year | 2023 |
---|---|
Principal Product | Dough Products |
NAICS | 311412: Frozen Specialty Food Manufacturing |
SIC | 2038: Frozen Specialties, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 275 |
Plant Area |
155,000
ft2
|
Annual Production | 2,600,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $411,920 | 10,697,005 |
kWh
|
$0.039 | |
Electricity Demand | $104,554 | 12,823 |
kW-mo/yr
|
$8.15 | |
Electricity Fees | $4,903 | - |
|
- | |
Natural Gas | $113,608 | 30,267 |
MMBtu
|
$3.75 | |
Waste Disposal Costs | |||||
Water Usage | $74,000 | 16,421 |
Tgal
|
$4.51 | |
Solid Waste (non-haz) | $90,000 | 260 |
lb
|
$346.15 | |
TOTAL YEARLY COSTS | $798,985 | ||||
RECOMMENDED SAVINGS* | $29,765 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.821: Pay bills on time to avoid late fees | $4,903 | - | - | - | - | $4,903 | |
02 | 2.7224: Reduce space conditioning during non-working hours | $196 | - | - | - |
$196
-
MMBtu
|
- | |
03 | 2.4239: Eliminate or reduce compressed air usage | $2,371 | - |
$2,371
61,580
kWh
|
- | - | - | |
04 | 2.2437: Recover waste heat from equipment | $7,559 | $291 | - | - |
$7,559
-
MMBtu
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,215 | $264 |
$3,215
83,519
kWh
|
- | - | - | |
06 | 2.4322: Use or replace with energy efficient substitutes | $920 | $80 |
$431
11,050
kWh
|
$489
-
kW-mo/yr
|
- | - | |
07 | 2.7314: Reduce ventilation air | $7,133 | $882 |
$2,122
55,106
kWh
|
- |
$5,012
-
MMBtu
|
- | |
08 | 2.4239: Eliminate or reduce compressed air usage | $1,150 | $812 |
$1,150
29,875
kWh
|
- | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $351 | $440 |
$162
4,205
kWh
|
$47
-
kW-mo/yr
|
- | $142 | |
10 | 2.6211: Conserve energy by efficient use of vending machines | $710 | $1,538 |
$710
18,430
kWh
|
- | - | - | |
11 | 2.7135: Install occupancy sensors | $137 | $394 |
$137
3,548
kWh
|
- | - | - | |
12 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,120 | $4,722 | - | - |
$1,120
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $29,765 | $9,423 |
$10,298
267,312
kWh
|
$536
-
kW-mo/yr
|
$13,886
-
MMBtu
|
$5,045 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs