Assessment Year | 2023 |
---|---|
Principal Product | Refrigeration Systems |
NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | $10 M to 50M |
# of Employees | 170 |
Plant Area |
76,400
ft2
|
Annual Production | 1,100
units
|
Production Hrs. Annual | 6,020
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $410,310 | 5,540,035 |
kWh
|
$0.074 |
Electricity Demand | $116,498 | 11,454 |
kW-mo/yr
|
$10.17 |
Electricity Fees | $43,438 | - |
|
- |
Natural Gas | $16,962 | 18,151 |
MMBtu
|
$0.93 |
TOTAL YEARLY COSTS | $587,208 | |||
RECOMMENDED SAVINGS* | $75,969 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $1,349 | - |
$1,349
18,200
kWh
|
- | - | - | |
02 | 2.7122: Disconnect ballasts | $14,156 | - |
$11,902
160,833
kWh
|
$2,254
-
kW-mo/yr
|
- | - | |
03 | 2.8121: Apply for tax-free status for energy purchases | $33,745 | $258 | - | - | - | $33,745 | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,692 | $502 |
$4,692
63,315
kWh
|
- | - | - | |
05 | 2.7135: Install occupancy sensors | $5,959 | $1,162 |
$5,959
80,417
kWh
|
- | - | - | |
06 | 2.8121: Apply for tax-free status for energy purchases | $1,005 | $258 | - | - | - | $1,005 | |
07 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,912 | $842 | - |
$2,912
-
kW-mo/yr
|
- | - | |
08 | 2.2437: Recover waste heat from equipment | $824 | $564 | - | - |
$824
-
MMBtu
|
- | |
09 | 2.6211: Conserve energy by efficient use of vending machines | $411 | $482 |
$411
5,552
kWh
|
- | - | - | |
10 | 2.4221: Install compressor air intakes in coolest locations | $640 | $1,152 |
$640
8,638
kWh
|
- | - | - | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,598 | $18,642 |
$2,598
35,064
kWh
|
- | - | - | |
12 | 2.9114: Use solar heat to make electricty | $7,678 | $100,000 |
$7,678
103,761
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $75,969 | $123,861 |
$35,228
475,779
kWh
|
$5,167
-
kW-mo/yr
|
$824
-
MMBtu
|
$34,750 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs