Assessment Year | 2023 |
---|---|
Principal Product | Industrial Laundry Equipment |
NAICS | 333310: Commercial and Service Industry Machinery Manufacturing |
SIC | 3582: Commercial Laundry, Drycleaning, and Pressing Machines |
Sales Range | $10 M to 50M |
# of Employees | 214 |
Plant Area |
255,000
ft2
|
Annual Production | 500
units
|
Production Hrs. Annual | 3,900
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $87,929 | 1,816,991 |
kWh
|
$0.048 |
Electricity Demand | $76,768 | 6,526 |
kW-mo/yr
|
$11.76 |
Electricity Fees | $12,478 | - |
|
- |
Natural Gas | $23,138 | 7,609 |
MMBtu
|
$3.04 |
LPG | $11,752 | 134 |
MMBtu
|
$87.90 |
TOTAL YEARLY COSTS | $212,065 | |||
RECOMMENDED SAVINGS* | $43,478 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7122: Disconnect ballasts | $670 | - |
$345
7,188
kWh
|
$325
-
kW-mo/yr
|
- | - | - | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $3,834 | - | - |
$3,834
-
kW-mo/yr
|
- | - | - | |
03 | 2.4322: Use or replace with energy efficient substitutes | $1,775 | $250 |
$1,224
25,500
kWh
|
$882
-
kW-mo/yr
|
$(-330.7)
-
MMBtu
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,688 | $6,050 |
$3,688
76,837
kWh
|
- | - | - | - | |
05 | 2.9114: Use solar heat to make electricty | $23,544 | $39,388 |
$9,432
196,500
kWh
|
$14,112
-
kW-mo/yr
|
- | - | - | |
06 | 2.7135: Install occupancy sensors | $158 | $274 |
$158
3,295
kWh
|
- | - | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,318 | $2,488 |
$393
8,190
kWh
|
$356
-
kW-mo/yr
|
- | - | $569 | |
08 | 2.1321: Replace fossil fuel equipment with electrical equipment | $8,392 | $24,000 |
$(-3,360.0)
(-70,000)
kWh
|
- | - |
$11,752
-
MMBtu
|
- | |
09 | 2.4221: Install compressor air intakes in coolest locations | $99 | $494 |
$99
2,052
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $43,478 | $72,944 |
$11,979
249,562
kWh
|
$19,509
-
kW-mo/yr
|
$(-330.7)
-
MMBtu
|
$11,752
-
MMBtu
|
$569 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs