Assessment Year | 2022 |
---|---|
Principal Product | Fused Cast Refractories |
NAICS | 327120: Clay Building Material and Refractories Manufacturing |
SIC | 3297: Nonclay Refractories |
Sales Range | $50 M to 100M |
# of Employees | 130 |
Plant Area |
300,600
ft2
|
Annual Production | 1,000,000
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $911,114 | 14,092,597 |
kWh
|
$0.065 | |
Electricity Demand | $1 | 50,379 |
kW-mo/yr
|
$0.000 | |
Electricity Fees | $7,211 | - |
|
- | |
Natural Gas | $183,094 | 50,267 |
MMBtu
|
$3.64 | |
Waste Disposal Costs | |||||
Water Usage | $8,760 | 1,200,000 |
Tgal
|
$0.007 | |
TOTAL YEARLY COSTS | $1,110,180 | ||||
RECOMMENDED SAVINGS* | $26,075 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7122: Disconnect ballasts | $3,507 | - |
$3,507
53,949
kWh
|
- | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $443 | - |
$443
7,536
kWh
|
- | - | - | |
03 | 2.7224: Reduce space conditioning during non-working hours | $46 | - | - |
$46
-
MMBtu
|
- | - | |
04 | 2.7314: Reduce ventilation air | $6,046 | $882 |
$2,380
36,616
kWh
|
$3,666
-
MMBtu
|
- | - | |
05 | 2.4322: Use or replace with energy efficient substitutes | $332 | $35 |
$437
6,720
kWh
|
$(-104.4)
-
MMBtu
|
- | - | |
06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,401 | $327 | - |
$1,401
-
MMBtu
|
- | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $478 | $485 |
$268
4,117
kWh
|
- | $109 | $101 | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,797 | $10,808 |
$8,702
133,870
kWh
|
- | - | $2,096 | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,341 | $1,479 |
$1,341
20,634
kWh
|
- | - | - | |
10 | 3.1161: Eliminate/reduce an operation | $1,433 | $2,000 |
$36
550
kWh
|
- | - | $1,397 | |
11 | 2.2136: Install / repair insulation on steam lines | $51 | $85 | - |
$51
-
MMBtu
|
- | - | |
12 | 2.6211: Conserve energy by efficient use of vending machines | $199 | $413 |
$199
3,066
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $26,075 | $16,514 |
$17,313
267,058
kWh
|
$5,060
-
MMBtu
|
$109 | $3,594 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs