| Assessment Year | 2020 |
|---|---|
| Principal Product | Vision and Multisensor Measuring Machines |
| NAICS | 333314: Optical Instrument and Lens Manufacturing |
| SIC | 3827: Optical Instruments and Lenses |
| Sales Range | $10 M to 50M |
| # of Employees | 320 |
| Plant Area |
181,200
ft2
|
| Annual Production | 25,000
units
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $106,673 | 2,918,067 |
kWh
|
$0.037 | |
| Electricity Demand | $151,087 | 12,103 |
kW-mo/yr
|
$12.48 | |
| Electricity Fees | $25,772 | - |
|
- | |
| Natural Gas | $36,984 | 6,045 |
MMBtu
|
$6.12 | |
| Waste Disposal Costs | |||||
| Water Usage | $13,250 | 1,080 |
Tgal
|
$12.27 | |
| Solid Waste (non-haz) | $14,550 | 500 |
lb
|
$29.10 | |
| Solid Waste (haz) | $27,630 | 250 |
lb
|
$110.52 | |
| TOTAL YEARLY COSTS | $375,946 | ||||
| RECOMMENDED SAVINGS* | $35,752 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $35,125 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4322: Use or replace with energy efficient substitutes | $7,584 | $534 |
$3,496
94,500
kWh
|
$6,553
-
kW-mo/yr
|
$(-2,465.0)
-
MMBtu
|
- | - | |
| 02 | 2.7314: Reduce ventilation air | $2,636 | $882 |
$732
19,797
kWh
|
- |
$1,904
-
MMBtu
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,448 | $4,525 |
$667
18,036
kWh
|
$307
-
kW-mo/yr
|
- | $977 | $496 | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $627 | $999 |
$627
16,946
kWh
|
- | - | - | - | |
| 05 | 3.1161: Eliminate/reduce an operation | $6,889 | $11,879 |
$(-170.9)
(-4,620)
kWh
|
$(-4,925.4)
-
kW-mo/yr
|
- | - | $11,985 | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,223 | $75,235 |
$5,119
138,346
kWh
|
$9,372
-
kW-mo/yr
|
- | $657 | $75 | |
| 07 | 2.6211: Conserve energy by efficient use of vending machines | $345 | $64 |
$345
9,330
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $35,752 | $94,118 |
$10,816
292,335
kWh
|
$11,307
-
kW-mo/yr
|
$(-561.1)
-
MMBtu
|
$1,634 | $12,556 | ||
| TOTAL IMPLEMENTED | $35,125 | $93,119 |
$10,189
275,389
kWh
|
$11,307
-
kW-mo/yr
|
$(-561.1)
-
MMBtu
|
$1,634 | $12,556 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs