Assessment Year | 2019 |
---|---|
Principal Product | Street Lighting/Plastic Housings |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 85 |
Plant Area |
86,000
ft2
|
Annual Production | 8,000,000
units
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $166,641 | 1,858,202 |
kWh
|
$0.090 | |
Electricity Demand | $11,660 | 2,952 |
kW-mo/yr
|
$3.95 | |
Electricity Fees | $655 | - |
|
- | |
Natural Gas | $94,418 | 12,746 |
MMBtu
|
$7.41 | |
Fuel Oil #2 | $15,946 | 732 |
MMBtu
|
$21.78 | |
Waste Disposal Costs | |||||
Water Usage | $3,416 | 800 |
Tgal
|
$4.27 | |
TOTAL YEARLY COSTS | $292,736 | ||||
RECOMMENDED SAVINGS* | $8,926 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $2,552 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $1,822 | $120 |
$2,041
22,680
kWh
|
$498
-
kW-mo/yr
|
$(-717.0)
-
MMBtu
|
- | |
02 | 2.4221: Install compressor air intakes in coolest locations | $1,069 | $641 |
$1,069
11,868
kWh
|
- | - | - | |
03 | 3.1161: Eliminate/reduce an operation | $3,489 | $2,300 |
$(-84.2)
(-936)
kWh
|
$(-246.5)
-
kW-mo/yr
|
- | $3,820 | |
04 | 2.2511: Insulate bare equipment | $318 | $295 | - | - |
$318
-
MMBtu
|
- | |
05 | 2.7314: Reduce ventilation air | $1,498 | $1,441 |
$975
10,830
kWh
|
- |
$523
-
MMBtu
|
- | |
06 | 2.6211: Conserve energy by efficient use of vending machines | $730 | $732 |
$730
8,111
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $8,926 | $5,529 |
$4,731
52,553
kWh
|
$252
-
kW-mo/yr
|
$124
-
MMBtu
|
$3,820 | ||
TOTAL IMPLEMENTED | $2,552 | $852 |
$2,771
30,791
kWh
|
$498
-
kW-mo/yr
|
$(-717.0)
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs