Assessment Year | 2019 |
---|---|
Principal Product | Pharma/Food Grade Products |
NAICS | 311999: All Other Miscellaneous Food Manufacturing |
SIC | 3826: Laboratory Analytical Instruments |
Sales Range | $50 M to 100M |
# of Employees | 124 |
Plant Area |
122,360
ft2
|
Annual Production | 14,000,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $203,411 | 5,657,192 |
kWh
|
$0.036 | |
Electricity Demand | $116,626 | 10,764 |
kW-mo/yr
|
$10.83 | |
Electricity Fees | $31,072 | - |
|
- | |
Natural Gas | $527,462 | 143,592 |
MMBtu
|
$3.67 | |
Waste Disposal Costs | |||||
Solid Waste (non-haz) | $553,200 | 1 |
lb
|
$553,200.00 | |
TOTAL YEARLY COSTS | $1,431,771 | ||||
RECOMMENDED SAVINGS* | $22,799 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $22,641 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.821: Pay bills on time to avoid late fees | $1,917 | - | - | - | - | - | $1,917 | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $498 | - |
$498
13,867
kWh
|
- | - | - | - | |
03 | 2.8121: Apply for tax-free status for energy purchases | $8,883 | $264 | - | - | - | - | $8,883 | |
04 | 2.4322: Use or replace with energy efficient substitutes | $975 | $90 |
$346
9,600
kWh
|
$780
-
kW-mo/yr
|
$(-150.0)
-
MMBtu
|
- | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $1,947 | $624 |
$1,947
54,086
kWh
|
- | - | - | - | |
06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $86 | $49 | - | - |
$86
-
MMBtu
|
- | - | |
07 | 3.1161: Eliminate/reduce an operation | $4,545 | $2,937 |
$(-48.0)
1,333
kWh
|
$(-389.9)
-
kW-mo/yr
|
- | - | $4,983 | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $397 | $576 |
$88
2,453
kWh
|
$37
-
kW-mo/yr
|
- | $182 | $90 | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,136 | $5,186 |
$2,145
59,604
kWh
|
$884
-
kW-mo/yr
|
- | - | $107 | |
10 | 2.7134: Use photocell controls | $256 | $460 |
$256
7,103
kWh
|
- | - | - | - | |
11 | 2.6211: Conserve energy by efficient use of vending machines | $110 | $357 |
$110
3,066
kWh
|
- | - | - | - | |
12 | 2.7224: Reduce space conditioning during non-working hours | $48 | $163 | - | - |
$48
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $22,799 | $10,705 |
$5,342
151,112
kWh
|
$1,310
-
kW-mo/yr
|
$(-15.7)
-
MMBtu
|
$182 | $15,980 | ||
TOTAL IMPLEMENTED | $22,641 | $10,185 |
$5,232
148,046
kWh
|
$1,310
-
kW-mo/yr
|
$(-64.0)
-
MMBtu
|
$182 | $15,980 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs