Assessment Year | 2019 |
---|---|
Principal Product | Ice Cream |
NAICS | 311520: Ice Cream and Frozen Dessert Manufacturing |
SIC | 2024: Ice Cream and Frozen Desserts |
Sales Range | $50 M to 100M |
# of Employees | 450 |
Plant Area |
250,000
ft2
|
Annual Production | 8,700
Tgal
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $1,311,522 | 37,492,736 |
kWh
|
$0.035 | |
Electricity Demand | $1,031,809 | 73,453 |
kW-mo/yr
|
$14.05 | |
Electricity Fees | $78,764 | - |
|
- | |
Natural Gas | $296,460 | 65,166 |
MMBtu
|
$4.55 | |
Waste Disposal Costs | |||||
Water Usage | $383,528 | 134 |
Tgal
|
$2,864.29 | |
Water Disposal | $1,408,346 | 1,000 |
Tgal
|
$1,408.35 | |
Solid Waste (non-haz) | $1,007,075 | 2,000 |
lb
|
$503.54 | |
TOTAL YEARLY COSTS | $5,517,504 | ||||
RECOMMENDED SAVINGS* | $26,631 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $13,476 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7122: Disconnect ballasts | $2,630 | - |
$1,580
45,144
kWh
|
$1,050
-
kW-mo/yr
|
- | - | - | |
02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,034 | $28 | - | - |
$1,034
-
MMBtu
|
- | - | |
03 | 2.2511: Insulate bare equipment | $1,779 | $1,023 | - | - |
$1,779
-
MMBtu
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,137 | $13,202 |
$7,280
208,008
kWh
|
$4,871
-
kW-mo/yr
|
- | - | $(-14.0) | |
05 | 3.1161: Eliminate/reduce an operation | $1,649 | $2,041 |
$(-14.0)
(-390)
kWh
|
$(-337.0)
-
kW-mo/yr
|
- | - | $2,000 | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $305 | $360 |
$123
3,504
kWh
|
$67
-
kW-mo/yr
|
- | $75 | $40 | |
07 | 2.7135: Install occupancy sensors | $640 | $1,168 |
$640
18,288
kWh
|
- | - | - | - | |
08 | 2.2414: Use waste heat from hot flue gases to preheat | $6,126 | $15,784 | - | - |
$6,126
-
MMBtu
|
- | - | |
09 | 2.6211: Conserve energy by efficient use of vending machines | $331 | $996 |
$331
9,471
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $26,631 | $34,602 |
$9,940
284,025
kWh
|
$5,651
-
kW-mo/yr
|
$8,939
-
MMBtu
|
$75 | $2,026 | ||
TOTAL IMPLEMENTED | $13,476 | $13,590 |
$7,403
211,512
kWh
|
$4,938
-
kW-mo/yr
|
$1,034
-
MMBtu
|
$75 | $26 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs