Assessment Year 2019
Principal Product MEMs Accelerometers
NAICS 334416: Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing
SIC 3676: Electronic Resistors
Sales Range $10
M
to 50
M
# of Employees 84
Plant Area 68,200
ft2
Annual Production 100
units
Production Hrs. Annual 4,368
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $339,275 7,470,933
kWh
Electricity Demand $138,775 12,724
kW-mo/yr
Electricity Fees $6,135 -
Natural Gas $25,245 3,573
MMBtu
TOTAL YEARLY COSTS $509,430
RECOMMENDED SAVINGS* $26,190 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,278

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $1,583 - $1,583
34,869
kWh
- - - -
02 2.7314: Reduce ventilation air $11,708 $882 $1,942
42,788
kWh
- $9,766
-
MMBtu
- -
03 2.4221: Install compressor air intakes in coolest locations $1,512 $1,311 $1,512
33,591
kWh
- - - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $922 $899 $406
8,935
kWh
$134
-
kW-mo/yr
- $182 $201
05 2.7135: Install occupancy sensors $1,917 $2,919 $1,917
42,241
kWh
- - - -
06 2.6211: Conserve energy by efficient use of vending machines $109 $200 $109
2,411
kWh
- - - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $8,439 $20,587 $4,944
108,906
kWh
$3,077
-
kW-mo/yr
- $558 $(-140.0)
TOTAL RECOMMENDED $26,190 $26,798 $12,413
273,741
kWh
$3,211
-
kW-mo/yr
$9,766
-
MMBtu
$740 $61
TOTAL IMPLEMENTED $11,278 $24,405 $7,267
160,082
kWh
$3,211
-
kW-mo/yr
- $740 $61
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs