Assessment Year | 2019 |
---|---|
Principal Product | Power generation equipment and piping |
NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 58 |
Plant Area |
51,250
ft2
|
Annual Production | 1,000
units
|
Production Hrs. Annual | 3,120
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $46,505 | 698,529 |
kWh
|
$0.067 |
Electricity Demand | $29,185 | 2,842 |
kW-mo/yr
|
$10.27 |
Electricity Fees | $3,684 | - |
|
- |
Other Gas | $79,265 | 4,002 |
MMBtu
|
$19.81 |
TOTAL YEARLY COSTS | $158,639 | |||
RECOMMENDED SAVINGS* | $12,848 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,323 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $733 | - |
$733
10,951
kWh
|
- | - | - | |
02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,486 | $300 | - | - |
$1,486
-
MMBtu
|
- | |
03 | 2.4322: Use or replace with energy efficient substitutes | $1,267 | $113 |
$1,206
18,000
kWh
|
$1,386
-
kW-mo/yr
|
$(-1,325.0)
-
MMBtu
|
- | |
04 | 2.2511: Insulate bare equipment | $6,520 | $500 | - | - |
$6,520
-
MMBtu
|
- | |
05 | 2.7224: Reduce space conditioning during non-working hours | $1,382 | $383 | - | - |
$1,382
-
MMBtu
|
- | |
06 | 2.2136: Install / repair insulation on steam lines | $584 | $500 | - | - |
$584
-
MMBtu
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $453 | $301 |
$223
3,329
kWh
|
$47
-
kW-mo/yr
|
- | $183 | |
08 | 2.6211: Conserve energy by efficient use of vending machines | $423 | $714 |
$423
6,314
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $12,848 | $2,811 |
$2,585
38,594
kWh
|
$1,433
-
kW-mo/yr
|
$8,647
-
MMBtu
|
$183 | ||
TOTAL IMPLEMENTED | $9,323 | $1,300 |
$733
10,951
kWh
|
- |
$8,590
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs