| Assessment Year | 2004 | 
|---|---|
| Principal Product | Ion Guns | 
| NAICS | 334516: Analytical Laboratory Instrument Manufacturing | 
| SIC | 3826: Laboratory Analytical Instruments | 
| Sales Range | $100 M  to 500M  | 
    
| # of Employees | 380 | 
| Plant Area | 
                            180,000
                 
ft2
 
                     | 
    
| Annual Production | 36
             
pieces
 
         | 
    
| Production Hrs. Annual | 2,080
             
hrs
 
         | 
    
| Location (State) | Oregon | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $411,223 | 8,186,800 | 
             
kWh
 
         | 
        $0.050 | 
| Electricity Demand | $73,093 | 14,530 | 
             
kW-mo/yr
 
         | 
        $5.03 | 
| Electricity Fees | $18,655 | - | 
             | 
        - | 
| Natural Gas | $12,256 | 1,398 | 
             
MMBtu
 
         | 
        $8.76 | 
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $2,682,130 | 
             See individual recommendations below 
            *Non-energy impacts included in savings.
         | 
    ||
| IMPLEMENTED SAVINGS* | $2,377,220 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings | 
|---|---|---|---|---|---|---|---|---|---|
| 01 | 4.111: Add equipment/ operators to reduce production bottleneck | $2,372,930 | $1,150 | - | - | $(-27,070.0) | - | $2,400,000 | |
| 02 | 4.652: Replace existing equipment with more suitable substitutes | $303,000 | $1,000 | - | - | - | $(-180,000.0) | $483,000 | |
| 03 | 2.6218: Turn off equipment when not in use | $4,290 | $2,690 | 
                        $3,640
                                                     72,550
                                 
                                            
kWh
 
                             | 
                                                                                
                        $650
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | - | - | |
| 04 | 2.7135: Install occupancy sensors | $1,910 | $875 | 
                        $1,910
                                                     38,100
                                 
                                            
kWh
 
                             | 
                                                                                - | - | - | - | |
| TOTAL RECOMMENDED | $2,682,130 | $5,715 | 
                        $5,550
                                                     110,650
                                 
                                            
kWh
 
                             | 
                                                                                
                        $650
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                $(-27,070.0) | $(-180,000.0) | $2,883,000 | ||
| TOTAL IMPLEMENTED | $2,377,220 | $3,840 | 
                        $3,640
                                                     72,550
                                 
                                            
kWh
 
                             | 
                                                                                
                        $650
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                $(-27,070.0) | - | $2,400,000 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs