Assessment Year 2018
Principal Product Wine
NAICS 312130: Wineries
SIC 2084: Wines, Brandy, and Brandy Spirits
Sales Range $100
M
to 500
M
# of Employees 155
Plant Area 350,000
ft2
Annual Production 20,000
units
Production Hrs. Annual 6,000
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $392,042 9,121,642
kWh
Electricity Demand $259,704 23,651
kW-mo/yr
Electricity Fees $63,305 -
Natural Gas $195,496 54,135
MMBtu
Waste Disposal Costs
Water Usage $1 40,155
Tgal
Solid Waste (haz) $43,000 1
lb
TOTAL YEARLY COSTS $953,548
RECOMMENDED SAVINGS* $50,122 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $33,105

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 4.821: Pay bills on time to avoid late fees $4,715 - - - - $4,715
02 2.2123: Insulate feedwater tank $1,339 $6,120 - - $1,339
-
MMBtu
-
03 2.7134: Use photocell controls $482 $265 $482
11,159
kWh
- - -
04 2.1336: Install equipment to utilize waste fuel $10,224 $10,000 - - $10,224
-
MMBtu
-
05 2.4221: Install compressor air intakes in coolest locations $1,377 $3,200 $1,377
31,884
kWh
- - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $25,355 $47,766 $11,697
270,765
kWh
$6,114
-
kW-mo/yr
- $7,544
07 2.6211: Conserve energy by efficient use of vending machines $208 $420 $208
4,818
kWh
- - -
08 2.2414: Use waste heat from hot flue gases to preheat $6,103 $15,784 - - $6,103
-
MMBtu
-
09 2.7135: Install occupancy sensors $319 $1,132 $319
7,392
kWh
- - -
TOTAL RECOMMENDED $50,122 $84,687 $14,083
326,018
kWh
$6,114
-
kW-mo/yr
$17,666
-
MMBtu
$12,259
TOTAL IMPLEMENTED $33,105 $58,218 $13,393
310,041
kWh
$6,114
-
kW-mo/yr
$1,339
-
MMBtu
$12,259
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs