Assessment Year | 2002 |
---|---|
Principal Product | Wiring Harnesses |
NAICS |
n/a
|
SIC | 3694: Electrical Equipment for Internal Combustion Engines |
Sales Range | $50 M to 100M |
# of Employees | 333 |
Plant Area |
140,000
ft2
|
Annual Production | 2,000
thousand feet
|
Production Hrs. Annual | 2,125
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $62,279 | 3,403,033 |
kWh
|
$0.018 |
Electricity Demand | $83,604 | 8,745 |
kW-mo/yr
|
$9.56 |
Electricity Fees | $(-5,324.0) | - |
|
- |
Natural Gas | $8,553 | 1,201 |
MMBtu
|
$7.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $62,559 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,721 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7124: Make a practice of turning off lights when not needed | $5,500 | - |
$1,370
76,500
kWh
|
$4,130
-
kW-mo/yr
|
- | - | |
02 | 4.424: Improve space comfort conditioning | $42,500 | $3,150 | - | - | - | $42,500 | |
03 | 2.7135: Install occupancy sensors | $258 | $717 |
$258
14,391
kWh
|
- | - | - | |
04 | 2.7226: Use computer programs to optimize hvac performance | $1,338 | $4,126 | - |
$1,338
-
kW-mo/yr
|
- | - | |
05 | 2.6232: Install set-back timers | $6,583 | $160 | - | - |
$6,583
-
MMBtu
|
- | |
06 | 2.7242: Change zone reheat coils to variable air volume boxes | $6,380 | $14,226 |
$6,380
356,454
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $62,559 | $22,379 |
$8,008
447,345
kWh
|
$5,468
-
kW-mo/yr
|
$6,583
-
MMBtu
|
$42,500 | ||
TOTAL IMPLEMENTED | $18,721 | $15,103 |
$8,008
447,345
kWh
|
$4,130
-
kW-mo/yr
|
$6,583
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs