Assessment Year | 2018 |
---|---|
Principal Product | Frozen Cheese Filled Pasta |
NAICS | 311412: Frozen Specialty Food Manufacturing |
SIC | 2038: Frozen Specialties, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 30 |
Plant Area |
60,000
ft2
|
Annual Production | 10,000,000
lb
|
Production Hrs. Annual | 5,330
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $101,796 | 2,134,486 |
kWh
|
$0.048 | |
Electricity Demand | $91,674 | 7,630 |
kW-mo/yr
|
$12.01 | |
Electricity Fees | $3,962 | - |
|
- | |
Natural Gas | $54,630 | 10,919 |
MMBtu
|
$5.00 | |
Waste Disposal Costs | |||||
Water Usage | $4,125 | 193 |
Tgal
|
$21.33 | |
TOTAL YEARLY COSTS | $256,187 | ||||
RECOMMENDED SAVINGS* | $8,067 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $4,238 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7224: Reduce space conditioning during non-working hours | $529 | $179 | - | - | - |
$529
-
MMBtu
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,460 | $2,625 |
$1,790
35,800
kWh
|
$1,004
-
kW-mo/yr
|
- | - | - | $666 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $247 | $271 |
$118
2,365
kWh
|
$38
-
kW-mo/yr
|
- | - | $64 | $26 | |
04 | 2.7135: Install occupancy sensors | $955 | $1,560 |
$955
19,095
kWh
|
- | - | - | - | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $703 | $1,240 |
$703
14,055
kWh
|
- | - | - | - | - | |
06 | 2.2123: Insulate feedwater tank | $75 | $172 | - | - | - |
$75
-
MMBtu
|
- | - | |
07 | 2.3212: Optimize plant power factor | $2,099 | $6,608 | - | - | $2,099 | - | - | - | |
TOTAL RECOMMENDED | $8,067 | $12,655 |
$3,566
71,315
kWh
|
$1,042
-
kW-mo/yr
|
$2,099 |
$604
-
MMBtu
|
$64 | $692 | ||
TOTAL IMPLEMENTED | $4,238 | $4,037 |
$2,493
49,855
kWh
|
$1,004
-
kW-mo/yr
|
- |
$75
-
MMBtu
|
- | $666 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs