ITAC Assessment: SU0454
ITAC logo
ITAC Assessment: SU0454
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2018
Principal Product Powdered/ Sintered Metal Products
NAICS 332117: Powder Metallurgy Part Manufacturing
SIC 3399: Primary Metal Products, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 52
Plant Area 50,000
ft2
Annual Production 2,732,000
lb
Production Hrs. Annual 6,240
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $214,383 2,706,000
kWh
Electricity Demand $47,296 6,593
kW-mo/yr
Electricity Fees $659 -
Natural Gas $23,880 9,366
MMBtu
TOTAL YEARLY COSTS $286,218
RECOMMENDED SAVINGS* $9,877 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,877

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
01 2.4131: Size electric motors for peak operating efficiency $4,250 $2,600 $4,250
53,664
kWh
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $3,562 $2,313 $2,718
34,320
kWh
$473
-
kW-mo/yr
$371
03 2.4221: Install compressor air intakes in coolest locations $631 $1,100 $631
7,991
kWh
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $201 $168 $132
1,664
kWh
$16
-
kW-mo/yr
$53
05 2.6211: Conserve energy by efficient use of vending machines $624 $702 $624
7,884
kWh
- -
06 2.7135: Install occupancy sensors $609 $1,336 $609
7,688
kWh
- -
TOTAL RECOMMENDED $9,877 $8,219 $8,964
113,211
kWh
$489
-
kW-mo/yr
$424
TOTAL IMPLEMENTED $9,877 $8,219 $8,964
113,211
kWh
$489
-
kW-mo/yr
$424
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs