| Assessment Year | 2017 |
|---|---|
| Principal Product | Workstation and Jib Cranes |
| NAICS | 333923: Overhead Traveling Crane, Hoist, and Monorail System Manufacturing |
| SIC | 3536: Overhead Traveling Cranes, Hoists, and Monorail Systems |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
119,500
ft2
|
| Annual Production | 7,500
units
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $64,028 | 1,209,437 |
kWh
|
$0.053 | |
| Electricity Demand | $96,503 | 6,866 |
kW-mo/yr
|
$14.06 | |
| Electricity Fees | $8,680 | - |
|
- | |
| Natural Gas | $62,198 | 10,459 |
MMBtu
|
$5.95 | |
| Waste Disposal Costs | |||||
| Water Usage | $895 | 217 |
Tgal
|
$4.12 | |
| TOTAL YEARLY COSTS | $232,304 | ||||
| RECOMMENDED SAVINGS* | $19,529 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $1,929 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $1,759 | - |
$1,759
33,187
kWh
|
- | - | - | - | |
| 02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $10,711 | $7,161 |
$17,363
327,600
kWh
|
- |
$(-6,652.0)
-
MMBtu
|
- | - | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $304 | $234 |
$304
5,739
kWh
|
- | - | - | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $170 | $165 |
$88
1,664
kWh
|
$32
-
kW-mo/yr
|
- | $30 | $20 | |
| 05 | 2.2314: Replace heat treating oven with more efficient unit | $6,295 | $18,204 | - | - |
$6,295
-
MMBtu
|
- | - | |
| 06 | 2.6211: Conserve energy by efficient use of vending machines | $290 | $854 |
$290
5,474
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $19,529 | $26,618 |
$19,804
373,664
kWh
|
$32
-
kW-mo/yr
|
$(-357.0)
-
MMBtu
|
$30 | $20 | ||
| TOTAL IMPLEMENTED | $1,929 | $165 |
$1,847
34,851
kWh
|
$32
-
kW-mo/yr
|
- | $30 | $20 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs