Assessment Year 2017
Principal Product Plastic Lab-ware
NAICS 326199: All Other Plastics Product Manufacturing
SIC 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers
Sales Range $50
M
to 100
M
# of Employees 174
Plant Area 130,000
ft2
Annual Production 170
ton
Production Hrs. Annual 7,488
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $346,637 11,292,023
kWh
Electricity Demand $219,903 28,431
kW-mo/yr
Natural Gas $7,520 1,334
MMBtu
Waste Disposal Costs
Water Usage $6,500 800
Tgal
TOTAL YEARLY COSTS $580,560
RECOMMENDED SAVINGS* $46,985 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $2,735 - $2,735
88,241
kWh
- - -
02 2.7122: Disconnect ballasts $1,881 - $1,344
43,355
kWh
$537
-
kW-mo/yr
- -
03 3.1161: Eliminate/reduce an operation $22,179 $350 $(-233.0)
(-7,500)
kWh
$(-278.0)
-
kW-mo/yr
$11,690 $11,000
04 2.7135: Install occupancy sensors $906 $968 $906
29,241
kWh
- - -
05 2.4221: Install compressor air intakes in coolest locations $4,680 $5,451 $4,680
150,982
kWh
- - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $14,489 $22,737 $7,280
234,824
kWh
$2,909
-
kW-mo/yr
$3,922 $378
07 2.6211: Conserve energy by efficient use of vending machines $115 $551 $115
3,723
kWh
- - -
TOTAL RECOMMENDED $46,985 $30,057 $16,827
542,866
kWh
$3,168
-
kW-mo/yr
$15,612 $11,378
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs