Assessment Year | 2002 |
---|---|
Principal Product | Corrugated Boxes |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
113,000
ft2
|
Annual Production | 525,000
thousand feet
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $184,743 | 3,185,280 |
kWh
|
$0.058 |
Electricity Demand | $18,704 | 7,943 |
kW-mo/yr
|
$2.35 |
Electricity Fees | $2,364 | - |
|
- |
Natural Gas | $153,162 | 29,671 |
MMBtu
|
$5.16 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $42,754 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,798 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $6,916 | $9,150 |
$6,497
122,737
kWh
|
$419
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.1123: Install automatic stack damper | $4,088 | $15,000 | - | - |
$4,088
-
MMBtu
|
- | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,525 | $1,000 |
$2,338
41,313
kWh
|
$187
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,064 | $140 |
$1,003
17,721
kWh
|
$61
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $917 | $1,000 |
$849
14,999
kWh
|
$68
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.7135: Install occupancy sensors | $690 | $900 |
$570
10,063
kWh
|
$120
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.7122: Disconnect ballasts | $653 | $240 |
$487
8,611
kWh
|
$139
-
kW-mo/yr
|
- | - | - | $27 | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $368 | $323 |
$207
3,662
kWh
|
$12
-
kW-mo/yr
|
- | - | - | $149 | |
09 | 2.2622: Replace existing chiller with high efficiency model | $2,449 | $11,500 | - | - | - |
$2,449
-
Tgal
|
- | - | |
10 | 3.2176: Increase use of automation | $22,464 | $45,000 | - | - | - | - | $22,464 | - | |
11 | 3.5316: Contract a wood pallet recycling company | $620 | $100 | - | - | - | - | - | $620 | |
TOTAL RECOMMENDED | $42,754 | $84,353 |
$11,951
219,106
kWh
|
$1,006
-
kW-mo/yr
|
$4,088
-
MMBtu
|
$2,449
-
Tgal
|
$22,464 | $796 | ||
TOTAL IMPLEMENTED | $3,798 | $1,340 |
$2,825
49,924
kWh
|
$326
-
kW-mo/yr
|
- | - | - | $647 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs