| Assessment Year | 2016 |
|---|---|
| Principal Product | Springs |
| NAICS | 332613: Spring Manufacturing |
| SIC | 3495: Wire Springs |
| Sales Range | $10 M to 50M |
| # of Employees | 70 |
| Plant Area |
32,000
ft2
|
| Annual Production | 500,000
units
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $67,407 | 1,030,836 |
kWh
|
$0.065 |
| Electricity Demand | $37,231 | 2,959 |
kW-mo/yr
|
$12.58 |
| Electricity Fees | $3,426 | - |
|
- |
| Natural Gas | $9,812 | 1,721 |
MMBtu
|
$5.70 |
| TOTAL YEARLY COSTS | $117,876 | |||
| RECOMMENDED SAVINGS* | $5,119 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,996 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.6231: Utilize controls to operate equipment only when needed | $31 | - |
$31
497
kWh
|
- | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $554 | $340 |
$239
3,679
kWh
|
$63
-
kW-mo/yr
|
$230 | $22 | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $73 | $74 |
$49
748
kWh
|
$24
-
kW-mo/yr
|
- | - | |
| 04 | 3.1161: Eliminate/reduce an operation | $3,431 | $3,650 |
$(-21.0)
(-320)
kWh
|
$(-145.0)
-
kW-mo/yr
|
$1,917 | $1,680 | |
| 05 | 2.6211: Conserve energy by efficient use of vending machines | $123 | $427 |
$123
1,893
kWh
|
- | - | - | |
| 06 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $848 | $3,260 |
$848
13,051
kWh
|
- | - | - | |
| 07 | 2.7135: Install occupancy sensors | $59 | $290 |
$59
915
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $5,119 | $8,041 |
$1,328
20,463
kWh
|
$(-58.0)
-
kW-mo/yr
|
$2,147 | $1,702 | ||
| TOTAL IMPLEMENTED | $4,996 | $7,614 |
$1,205
18,570
kWh
|
$(-58.0)
-
kW-mo/yr
|
$2,147 | $1,702 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs