Assessment Year | 2016 |
---|---|
Principal Product | Frames |
NAICS | 337215: Showcase, Partition, Shelving, and Locker Manufacturing |
SIC | 2499: Wood Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 170 |
Plant Area |
226,000
ft2
|
Annual Production | 659,766
units
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $58,115 | 1,328,619 |
kWh
|
$0.044 |
Electricity Demand | $51,046 | 5,493 |
kW-mo/yr
|
$9.29 |
Electricity Fees | $(-28,200.0) | - |
|
- |
Natural Gas | $26,838 | 4,451 |
MMBtu
|
$6.03 |
TOTAL YEARLY COSTS | $107,799 | |||
RECOMMENDED SAVINGS* | $99,172 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 4.821: Pay bills on time to avoid late fees | $50 | - | - | - | - | - | $50 | - | |
02 | 2.7122: Disconnect ballasts | $321 | - |
$154
3,510
kWh
|
$167
-
kW-mo/yr
|
- | - | - | - | |
03 | 3.1192: Reduce scrap production | $79,948 | $15,445 | - | - | - | - | - | $79,948 | |
04 | 2.7134: Use photocell controls | $142 | $45 |
$142
3,220
kWh
|
- | - | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $553 | $229 |
$127
2,890
kWh
|
$37
-
kW-mo/yr
|
- | $324 | $65 | - | |
06 | 2.7135: Install occupancy sensors | $991 | $384 |
$991
22,534
kWh
|
- | - | - | - | - | |
07 | 2.7444: Close holes and openings in building such as broken windows | $51 | $53 | - | - |
$51
-
MMBtu
|
- | - | - | |
08 | 2.6211: Conserve energy by efficient use of vending machines | $717 | $872 |
$717
16,289
kWh
|
- | - | - | - | - | |
09 | 2.7314: Reduce ventilation air | $374 | $875 |
$68
1,543
kWh
|
- |
$306
-
MMBtu
|
- | - | - | |
10 | 2.4221: Install compressor air intakes in coolest locations | $396 | $1,514 |
$396
9,004
kWh
|
- | - | - | - | - | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,629 | $71,075 |
$8,638
196,326
kWh
|
$9,359
-
kW-mo/yr
|
- | $424 | $(-2,792.0) | - | |
TOTAL RECOMMENDED | $99,172 | $90,492 |
$11,233
255,316
kWh
|
$9,563
-
kW-mo/yr
|
$357
-
MMBtu
|
$748 | $(-2,677.0) | $79,948 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs