Assessment Year | 2015 |
---|---|
Principal Product | Sheet Metal Fabrication Equipment |
NAICS | 333517: Machine Tool Manufacturing |
SIC | 3542: Machine Tools, Metal Forming Types |
Sales Range | $10 M to 50M |
# of Employees | 108 |
Plant Area |
250,000
ft2
|
Annual Production | 40
units
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $120,475 | 2,882,400 |
kWh
|
$0.042 |
Electricity Demand | $16,506 | 7,457 |
kW-mo/yr
|
$2.21 |
Electricity Fees | $515 | - |
|
- |
Natural Gas | $81,564 | 15,212 |
MMBtu
|
$5.36 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $33,808 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,862 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $851 | - |
$652
15,600
kWh
|
$199
-
kW-mo/yr
|
- | - | |
02 | 2.7122: Disconnect ballasts | $375 | - |
$287
6,864
kWh
|
$88
-
kW-mo/yr
|
- | - | |
03 | 2.2437: Recover waste heat from equipment | $6,073 | $600 | - | - |
$6,073
-
MMBtu
|
- | |
04 | 2.7135: Install occupancy sensors | $1,500 | $297 |
$1,500
35,880
kWh
|
- | - | - | |
05 | 2.7314: Reduce ventilation air | $8,182 | $2,941 |
$1,562
37,373
kWh
|
- |
$6,620
-
MMBtu
|
- | |
06 | 3.1161: Eliminate/reduce an operation | $5,835 | $2,320 |
$(-1,016.0)
(-24,300)
kWh
|
$(-80.0)
-
kW-mo/yr
|
- | $6,931 | |
07 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $770 | $950 |
$770
18,428
kWh
|
- | - | - | |
08 | 2.7292: Lower ceiling to reduce conditioned space | $1,495 | $2,000 |
$1,495
35,754
kWh
|
- | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $431 | $560 |
$176
4,205
kWh
|
$13
-
kW-mo/yr
|
- | $242 | |
10 | 2.4321: Upgrade obsolete equipment | $7,911 | $23,244 | - | - |
$7,911
-
MMBtu
|
- | |
11 | 2.4221: Install compressor air intakes in coolest locations | $385 | $1,496 |
$385
9,214
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $33,808 | $34,408 |
$5,811
139,018
kWh
|
$220
-
kW-mo/yr
|
$20,604
-
MMBtu
|
$7,173 | ||
TOTAL IMPLEMENTED | $24,862 | $30,295 |
$4,003
95,760
kWh
|
$13
-
kW-mo/yr
|
$20,604
-
MMBtu
|
$242 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs