Assessment Year | 2015 |
---|---|
Principal Product | Commercial Printing |
NAICS | 323111: Commercial Printing (except Screen and Books) |
SIC | 2759: Commercial Printing, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 74 |
Plant Area |
35,000
ft2
|
Annual Production | 39,000,000
units
|
Production Hrs. Annual | 4,080
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $50,325 | 1,353,202 |
kWh
|
$0.037 |
Electricity Demand | $68,410 | 5,277 |
kW-mo/yr
|
$12.96 |
Electricity Fees | $25,912 | - |
|
- |
Natural Gas | $12,054 | 1,621 |
MMBtu
|
$7.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,378 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,378 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.821: Pay bills on time to avoid late fees | $4,042 | - | - | - | - | - | $4,042 | |
02 | 2.7224: Reduce space conditioning during non-working hours | $1,055 | - | - | - |
$1,055
-
MMBtu
|
- | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $646 | - |
$646
17,353
kWh
|
- | - | - | - | |
04 | 2.7221: Lower temperature during the winter season and vice-versa | $184 | - |
$184
4,938
kWh
|
- | - | - | - | |
05 | 2.6212: Turn off equipment during breaks, reduce operating time | $43 | - |
$43
1,156
kWh
|
- | - | - | - | |
06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $606 | $100 | - | - |
$606
-
MMBtu
|
- | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $464 | $223 |
$91
2,453
kWh
|
$44
-
kW-mo/yr
|
- | $241 | $88 | |
08 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $251 | $654 |
$191
5,133
kWh
|
- | - | $33 | $27 | |
09 | 2.6211: Conserve energy by efficient use of vending machines | $108 | $281 |
$108
2,890
kWh
|
- | - | - | - | |
10 | 2.7314: Reduce ventilation air | $234 | $794 |
$38
1,034
kWh
|
- |
$196
-
MMBtu
|
- | - | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,745 | $8,154 |
$530
14,247
kWh
|
$548
-
kW-mo/yr
|
- | $217 | $450 | |
TOTAL RECOMMENDED | $9,378 | $10,206 |
$1,831
49,204
kWh
|
$592
-
kW-mo/yr
|
$1,857
-
MMBtu
|
$491 | $4,607 | ||
TOTAL IMPLEMENTED | $9,378 | $10,206 |
$1,831
49,204
kWh
|
$592
-
kW-mo/yr
|
$1,857
-
MMBtu
|
$491 | $4,607 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs