Assessment Year 2015
Principal Product Commercial Printing
NAICS 323111: Commercial Printing (except Screen and Books)
SIC 2759: Commercial Printing, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 74
Plant Area 35,000
ft2
Annual Production 39,000,000
units
Production Hrs. Annual 4,080
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $50,325 1,353,202
kWh
Electricity Demand $68,410 5,277
kW-mo/yr
Electricity Fees $25,912 -
Natural Gas $12,054 1,621
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $9,378 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,378

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 4.821: Pay bills on time to avoid late fees $4,042 - - - - - $4,042
02 2.7224: Reduce space conditioning during non-working hours $1,055 - - - $1,055
-
MMBtu
- -
03 2.4231: Reduce the pressure of compressed air to the minimum required $646 - $646
17,353
kWh
- - - -
04 2.7221: Lower temperature during the winter season and vice-versa $184 - $184
4,938
kWh
- - - -
05 2.6212: Turn off equipment during breaks, reduce operating time $43 - $43
1,156
kWh
- - - -
06 2.7447: Install vinyl strip / high speed / air curtain doors $606 $100 - - $606
-
MMBtu
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $464 $223 $91
2,453
kWh
$44
-
kW-mo/yr
- $241 $88
08 2.7121: Utilize daylight whenever possible in lieu of artificial light $251 $654 $191
5,133
kWh
- - $33 $27
09 2.6211: Conserve energy by efficient use of vending machines $108 $281 $108
2,890
kWh
- - - -
10 2.7314: Reduce ventilation air $234 $794 $38
1,034
kWh
- $196
-
MMBtu
- -
11 2.7142: Utilize higher efficiency lamps and/or ballasts $1,745 $8,154 $530
14,247
kWh
$548
-
kW-mo/yr
- $217 $450
TOTAL RECOMMENDED $9,378 $10,206 $1,831
49,204
kWh
$592
-
kW-mo/yr
$1,857
-
MMBtu
$491 $4,607
TOTAL IMPLEMENTED $9,378 $10,206 $1,831
49,204
kWh
$592
-
kW-mo/yr
$1,857
-
MMBtu
$491 $4,607
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings