Assessment Year 2015
Principal Product Injection Molded Plastic Component Parts
NAICS 326121: Unlaminated Plastics Profile Shape Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $100
M
to 500
M
# of Employees 907
Plant Area 900,173
ft2
Annual Production 2,275,000,000
pieces
Production Hrs. Annual 6,240
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $2,370,757 56,064,161
kWh
Electricity Demand $664,089 169,892
kW-mo/yr
Electricity Fees $(-29,390.0) -
Natural Gas $100,620 14,032
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $27,221 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $19,613

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $5,788 - $5,788
137,819
kWh
- - - -
02 2.7122: Disconnect ballasts $1,418 - $1,203
28,641
kWh
$215
-
kW-mo/yr
- - -
03 2.4322: Use or replace with energy efficient substitutes $516 - $340
8,100
kWh
$176
-
kW-mo/yr
- - -
04 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings $10,554 $3,085 $10,554
251,288
kWh
- - - -
05 2.7135: Install occupancy sensors $402 $158 $402
9,579
kWh
- - - -
06 2.4221: Install compressor air intakes in coolest locations $4,731 $2,974 $4,731
112,643
kWh
- - - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $3,064 $2,148 $773
18,396
kWh
$99
-
kW-mo/yr
- $1,532 $660
08 2.2136: Install / repair insulation on steam lines $119 $123 - - $119
-
MMBtu
- -
09 2.6211: Conserve energy by efficient use of vending machines $372 $804 $372
8,850
kWh
- - - -
10 2.4321: Upgrade obsolete equipment $257 $1,070 $228
5,431
kWh
$29
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $27,221 $10,362 $24,391
580,747
kWh
$519
-
kW-mo/yr
$119
-
MMBtu
$1,532 $660
TOTAL IMPLEMENTED $19,613 $10,204 $16,998
404,708
kWh
$304
-
kW-mo/yr
$119
-
MMBtu
$1,532 $660
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs