| Assessment Year | 2015 |
|---|---|
| Principal Product | Garden Sprayers/Foggers |
| NAICS | 333111: Farm Machinery and Equipment Manufacturing |
| SIC | 3523: Farm Machinery and Equipment |
| Sales Range | $100 M to 500M |
| # of Employees | 194 |
| Plant Area |
212,000
ft2
|
| Annual Production | 2,500,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $115,585 | 3,210,914 |
kWh
|
$0.036 |
| Electricity Demand | $71,694 | 8,645 |
kW-mo/yr
|
$8.29 |
| Electricity Fees | $5,757 | - |
|
- |
| Natural Gas | $38,243 | 5,561 |
MMBtu
|
$6.88 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $14,431 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,431 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $3,837 | - | - | - | - | $3,837 | |
| 02 | 2.8121: Apply for tax-free status for energy purchases | $2,454 | - | - | - | - | $2,454 | |
| 03 | 2.4314: Use synthetic lubricant | $2,140 | - |
$1,483
41,184
kWh
|
$657
-
kW-mo/yr
|
- | - | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,252 | - |
$1,252
34,771
kWh
|
- | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $638 | $245 |
$28
788
kWh
|
$9
-
kW-mo/yr
|
$504 | $97 | |
| 06 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $2,504 | $2,012 |
$2,504
69,542
kWh
|
- | - | - | |
| 07 | 2.4221: Install compressor air intakes in coolest locations | $1,502 | $2,362 |
$1,502
41,726
kWh
|
- | - | - | |
| 08 | 2.4321: Upgrade obsolete equipment | $104 | $463 |
$79
2,190
kWh
|
$25
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $14,431 | $5,082 |
$6,848
190,201
kWh
|
$691
-
kW-mo/yr
|
$504 | $6,388 | ||
| TOTAL IMPLEMENTED | $8,431 | $2,607 |
$1,530
42,514
kWh
|
$9
-
kW-mo/yr
|
$504 | $6,388 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs