Assessment Year | 1992 |
---|---|
Principal Product | PVC AND ABS PIPE FITTING |
NAICS |
n/a
|
SIC | 3088: Plastics Plumbing Fixtures |
Sales Range | $5 M to 10M |
# of Employees | 70 |
Plant Area |
n/a
|
Annual Production | 6,500,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $190,568 | 4,052,755 |
kWh
|
$0.047 |
Natural Gas | $12,680 | 3,089 |
MMBtu
|
$4.10 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,537 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,063 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $2,788 | $7,000 |
$2,788
59,203
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $474 | $654 |
$619
13,189
kWh
|
$(-145.0) | |
03 | 2.6232: Install set-back timers | $517 | $200 |
$517
11,137
kWh
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $758 | $500 |
$758
16,120
kWh
|
- | |
TOTAL RECOMMENDED | $4,537 | $8,354 |
$4,682
99,649
kWh
|
$(-145.0) | ||
TOTAL IMPLEMENTED | $4,063 | $7,700 |
$4,063
86,460
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs