Assessment Year | 2015 |
---|---|
Principal Product | Airguns and Ammunition |
NAICS | 332992: Small Arms Ammunition Manufacturing |
SIC | 3482: Small Arms Ammunition |
Sales Range | $1 M to 5M |
# of Employees | 300 |
Plant Area |
238,000
ft2
|
Annual Production | 7,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $409,528 | 7,478,915 |
kWh
|
$0.055 |
Electricity Demand | $237,661 | 17,302 |
kW-mo/yr
|
$13.74 |
Natural Gas | $75,498 | 14,969 |
MMBtu
|
$5.04 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,560 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4314: Use synthetic lubricant | $362 | - |
$148
2,704
kWh
|
$214
-
kW-mo/yr
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,982 | $1,901 |
$7,982
145,656
kWh
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $394 | $320 |
$168
3,066
kWh
|
$58
-
kW-mo/yr
|
- | $168 | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,679 | $10,400 |
$1,896
34,602
kWh
|
$1,305
-
kW-mo/yr
|
- | $1,478 | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $220 | $624 |
$46
832
kWh
|
$53
-
kW-mo/yr
|
- | $121 | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $461 | $1,590 |
$214
3,900
kWh
|
$247
-
kW-mo/yr
|
- | - | |
07 | 2.7135: Install occupancy sensors | $394 | $1,415 |
$394
7,183
kWh
|
- | - | - | |
08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $68 | $324 | - | - |
$68
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $14,560 | $16,574 |
$10,848
197,943
kWh
|
$1,877
-
kW-mo/yr
|
$68
-
MMBtu
|
$1,767 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs