Assessment Year 2014
Principal Product Commercial Printing and Packaging
NAICS 323111: Commercial Printing (except Screen and Books)
SIC 2759: Commercial Printing, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 50
Plant Area 150,000
ft2
Annual Production 16,103
thousand feet
Production Hrs. Annual 6,240
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $66,040 1,808,318
kWh
Electricity Demand $68,462 5,681
kW-mo/yr
Electricity Fees $16,909 -
Natural Gas $26,302 3,426
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $10,561 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,166

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings
01 2.4322: Use or replace with energy efficient substitutes $799 - $148
4,050
kWh
$651
-
kW-mo/yr
-
02 2.4231: Reduce the pressure of compressed air to the minimum required $302 - $302
8,265
kWh
- -
03 2.7111: Reduce illumination to minimum necessary levels $4,771 $693 $2,915
79,872
kWh
$1,856
-
kW-mo/yr
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $731 $682 $256
7,008
kWh
$116
-
kW-mo/yr
$359
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $603 $775 $603
16,529
kWh
- -
06 2.7135: Install occupancy sensors $102 $180 $102
2,808
kWh
- -
07 2.7134: Use photocell controls $296 $816 $296
8,112
kWh
- -
08 2.4221: Install compressor air intakes in coolest locations $410 $1,324 $410
11,224
kWh
- -
09 2.6211: Conserve energy by efficient use of vending machines $112 $399 $112
3,075
kWh
- -
10 2.7142: Utilize higher efficiency lamps and/or ballasts $2,435 $10,106 $1,073
29,392
kWh
$681
-
kW-mo/yr
$681
TOTAL RECOMMENDED $10,561 $14,975 $6,217
170,335
kWh
$3,304
-
kW-mo/yr
$1,040
TOTAL IMPLEMENTED $3,166 $10,788 $1,329
36,400
kWh
$797
-
kW-mo/yr
$1,040
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs