Assessment Year | 2014 |
---|---|
Principal Product | Commercial Printing and Packaging |
NAICS | 323111: Commercial Printing (except Screen and Books) |
SIC | 2759: Commercial Printing, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
150,000
ft2
|
Annual Production | 16,103
thousand feet
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $66,040 | 1,808,318 |
kWh
|
$0.037 |
Electricity Demand | $68,462 | 5,681 |
kW-mo/yr
|
$12.05 |
Electricity Fees | $16,909 | - |
|
- |
Natural Gas | $26,302 | 3,426 |
MMBtu
|
$7.68 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,561 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,166 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $799 | - |
$148
4,050
kWh
|
$651
-
kW-mo/yr
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $302 | - |
$302
8,265
kWh
|
- | - | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $4,771 | $693 |
$2,915
79,872
kWh
|
$1,856
-
kW-mo/yr
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $731 | $682 |
$256
7,008
kWh
|
$116
-
kW-mo/yr
|
$359 | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $603 | $775 |
$603
16,529
kWh
|
- | - | |
06 | 2.7135: Install occupancy sensors | $102 | $180 |
$102
2,808
kWh
|
- | - | |
07 | 2.7134: Use photocell controls | $296 | $816 |
$296
8,112
kWh
|
- | - | |
08 | 2.4221: Install compressor air intakes in coolest locations | $410 | $1,324 |
$410
11,224
kWh
|
- | - | |
09 | 2.6211: Conserve energy by efficient use of vending machines | $112 | $399 |
$112
3,075
kWh
|
- | - | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,435 | $10,106 |
$1,073
29,392
kWh
|
$681
-
kW-mo/yr
|
$681 | |
TOTAL RECOMMENDED | $10,561 | $14,975 |
$6,217
170,335
kWh
|
$3,304
-
kW-mo/yr
|
$1,040 | ||
TOTAL IMPLEMENTED | $3,166 | $10,788 |
$1,329
36,400
kWh
|
$797
-
kW-mo/yr
|
$1,040 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs