Assessment Year | 1998 |
---|---|
Principal Product | Various types of Envelopes |
NAICS |
n/a
|
SIC | 2677: Envelopes |
Sales Range | $10 M to 50M |
# of Employees | 275 |
Plant Area |
101,000
ft2
|
Annual Production | 2,500,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $316,804 | 6,802,755 |
kWh
|
$0.047 |
Electricity Demand | $30,292 | 1,220 |
kW-mo/yr
|
$24.83 |
Electricity Fees | $28,987 | - |
|
- |
Natural Gas | $20,864 | 3,643 |
MMBtu
|
$5.73 |
LPG | $6,841 | 453 |
MMBtu
|
$15.10 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $162,762 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,812 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.611: Begin a practice of predictive / preventative maintenance | $2,820 | $3,700 | - | - | - | $2,820 | |
02 | 4.514: Re-arrange equipment layout to reduce handling costs | $6,875 | $9,000 | - | - | - | $6,875 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,275 | $5,648 |
$1,952
38,394
kWh
|
$323
-
kW-mo/yr
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $958 | $1,308 |
$834
16,413
kWh
|
$124
-
kW-mo/yr
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $129 | $207 |
$104
2,052
kWh
|
$25
-
kW-mo/yr
|
- | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $3,303 | $128 |
$3,055
60,082
kWh
|
$248
-
kW-mo/yr
|
- | - | |
07 | 2.4133: Use most efficient type of electric motors | $5,051 | $6,765 |
$4,679
92,028
kWh
|
$372
-
kW-mo/yr
|
- | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,276 | - |
$1,177
23,154
kWh
|
$99
-
kW-mo/yr
|
- | - | |
09 | 3.1163: Use plastic pallets instead of wood | $138,000 | $129,420 | - | - |
$138,000
-
lb
|
- | |
10 | 3.1175: Use a different or recycled raw material | $2,075 | - | - | - |
$2,075
-
lb
|
- | |
TOTAL RECOMMENDED | $162,762 | $156,176 |
$11,801
232,123
kWh
|
$1,191
-
kW-mo/yr
|
$140,075
-
lb
|
$9,695 | ||
TOTAL IMPLEMENTED | $15,812 | $17,756 |
$11,801
232,123
kWh
|
$1,191
-
kW-mo/yr
|
- | $2,820 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs