| Assessment Year | 2014 |
|---|---|
| Principal Product | Single use medical devices |
| NAICS | 339112: Surgical and Medical Instrument Manufacturing |
| SIC | 3841: Surgical and Medical Instruments and Apparatus |
| Sales Range | $10 M to 50M |
| # of Employees | 415 |
| Plant Area |
67,030
ft2
|
| Annual Production | 53,158,717
pieces
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $263,571 | 5,322,787 |
kWh
|
$0.050 |
| Electricity Demand | $45,655 | 11,774 |
kW-mo/yr
|
$3.88 |
| Electricity Fees | $22,275 | - |
|
- |
| Natural Gas | $6,735 | 666 |
MMBtu
|
$10.11 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,802 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,061 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $1,976 | - | - | - | - | - | $1,976 | |
| 02 | 2.7224: Reduce space conditioning during non-working hours | $647 | - | - | - |
$647
-
MMBtu
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,108 | $493 |
$3,108
62,160
kWh
|
- | - | - | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $1,741 | $663 |
$1,741
34,829
kWh
|
- | - | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $794 | $461 |
$127
2,541
kWh
|
$14
-
kW-mo/yr
|
- | $653 | - | |
| 06 | 2.6211: Conserve energy by efficient use of vending machines | $181 | $287 |
$181
3,612
kWh
|
- | - | - | - | |
| 07 | 2.7135: Install occupancy sensors | $1,119 | $2,541 |
$1,119
22,386
kWh
|
- | - | - | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $236 | $677 |
$180
3,598
kWh
|
$56
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $9,802 | $5,122 |
$6,456
129,126
kWh
|
$70
-
kW-mo/yr
|
$647
-
MMBtu
|
$653 | $1,976 | ||
| TOTAL IMPLEMENTED | $8,061 | $4,459 |
$4,715
94,297
kWh
|
$70
-
kW-mo/yr
|
$647
-
MMBtu
|
$653 | $1,976 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs