Assessment Year | 2014 |
---|---|
Principal Product | Plastic Bottles and Caps |
NAICS | 326160: Plastics Bottle Manufacturing |
SIC | 3085: Plastics Bottles |
Sales Range | $10 M to 50M |
# of Employees | 125 |
Plant Area |
117,350
ft2
|
Annual Production | 983,000,000
pieces
|
Production Hrs. Annual | 8,640
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $501,578 | 9,917,215 |
kWh
|
$0.051 |
Electricity Demand | $131,509 | 18,195 |
kW-mo/yr
|
$7.23 |
Electricity Fees | $16,475 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,782 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,308 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 3.1161: Eliminate/reduce an operation | $347 | - |
$289
5,702
kWh
|
$58
-
kW-mo/yr
|
- | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $13,384 | $3,267 |
$13,384
264,504
kWh
|
- | - | - | |
03 | 2.7135: Install occupancy sensors | $797 | $590 |
$797
15,759
kWh
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $164 | $114 |
$49
963
kWh
|
$7
-
kW-mo/yr
|
$73 | $35 | |
05 | 3.1161: Eliminate/reduce an operation | $3,205 | $3,000 |
$(-142.0)
(-2,805)
kWh
|
$(-260.0)
-
kW-mo/yr
|
$275 | $3,332 | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $688 | $2,000 |
$688
13,600
kWh
|
- | - | - | |
07 | 2.6211: Conserve energy by efficient use of vending machines | $197 | $568 |
$197
3,895
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $18,782 | $9,539 |
$15,262
301,618
kWh
|
$(-195.0)
-
kW-mo/yr
|
$348 | $3,367 | ||
TOTAL IMPLEMENTED | $1,308 | $704 |
$1,135
22,424
kWh
|
$65
-
kW-mo/yr
|
$73 | $35 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs