Assessment Year 2014
Principal Product Plastic Bottles and Caps
NAICS 326160: Plastics Bottle Manufacturing
SIC 3085: Plastics Bottles
Sales Range $10
M
to 50
M
# of Employees 125
Plant Area 117,350
ft2
Annual Production 983,000,000
pieces
Production Hrs. Annual 8,640
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $501,578 9,917,215
kWh
Electricity Demand $131,509 18,195
kW-mo/yr
Electricity Fees $16,475 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $18,782 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,308

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 3.1161: Eliminate/reduce an operation $347 - $289
5,702
kWh
$58
-
kW-mo/yr
- -
02 2.4221: Install compressor air intakes in coolest locations $13,384 $3,267 $13,384
264,504
kWh
- - -
03 2.7135: Install occupancy sensors $797 $590 $797
15,759
kWh
- - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $164 $114 $49
963
kWh
$7
-
kW-mo/yr
$73 $35
05 3.1161: Eliminate/reduce an operation $3,205 $3,000 $(-142.0)
(-2,805)
kWh
$(-260.0)
-
kW-mo/yr
$275 $3,332
06 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $688 $2,000 $688
13,600
kWh
- - -
07 2.6211: Conserve energy by efficient use of vending machines $197 $568 $197
3,895
kWh
- - -
TOTAL RECOMMENDED $18,782 $9,539 $15,262
301,618
kWh
$(-195.0)
-
kW-mo/yr
$348 $3,367
TOTAL IMPLEMENTED $1,308 $704 $1,135
22,424
kWh
$65
-
kW-mo/yr
$73 $35
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs