| Assessment Year | 2010 |
|---|---|
| Principal Product | Animal Vaccines |
| NAICS | 325414: Biological Product (except Diagnostic) Manufacturing |
| SIC | 2836: Biological Products, Except Diagnostic Substances |
| Sales Range | $1 M to 5M |
| # of Employees | 300 |
| Plant Area |
94,000
ft2
|
| Annual Production | 6
Tgal
|
| Production Hrs. Annual | 8,766
hrs
|
| Location (State) | Delaware |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,511,947 | 14,389,115 |
kWh
|
$0.11 |
| Natural Gas | $362,987 | 31,691 |
MMBtu
|
$11.45 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $69,582 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,900 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $10,000 | $2,500 | - |
$10,000
-
MMBtu
|
- | |
| 02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $14,000 | $15,930 |
$14,000
129,000
kWh
|
- | - | |
| 03 | 2.2314: Replace heat treating oven with more efficient unit | $10,000 | $6,300 |
$10,000
96,000
kWh
|
- | - | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $8,200 | $10,000 |
$8,200
76,300
kWh
|
- | - | |
| 05 | 2.2414: Use waste heat from hot flue gases to preheat | $8,400 | $15,300 | - |
$8,400
-
MMBtu
|
- | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $6,000 | $5,000 |
$6,000
56,500
kWh
|
- | - | |
| 07 | 3.4114: Replace city water with recycled water via cooling tower | $3,500 | $1,000 | - | - |
$3,500
-
Tgal
|
|
| 08 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,900 | $30 |
$1,900
17,500
kWh
|
- | - | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $649 | $1,331 |
$649
6,070
kWh
|
- | - | |
| 10 | 2.7313: Recycle air for heating, ventilation and air conditioning | $1,200 | $2,500 | - |
$1,200
-
MMBtu
|
- | |
| 11 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $2,800 | $10,000 |
$2,800
26,000
kWh
|
- | - | |
| 12 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,700 | $10,000 | - |
$2,700
-
MMBtu
|
- | |
| 13 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $233 | $970 |
$233
2,182
kWh
|
- | - | |
| TOTAL RECOMMENDED | $69,582 | $80,861 |
$43,782
409,552
kWh
|
$22,300
-
MMBtu
|
$3,500
-
Tgal
|
||
| TOTAL IMPLEMENTED | $7,900 | $5,030 |
$7,900
74,000
kWh
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs