ITAC Assessment: SU0351
ITAC logo
ITAC Assessment: SU0351
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2013
Principal Product Labels, Wraps, and Cartons
NAICS 323111: Commercial Printing (except Screen and Books)
SIC 2791: Typesetting
Sales Range $10
M
to 50
M
# of Employees 90
Plant Area 37,500
ft2
Annual Production 150,000
thousand feet
Production Hrs. Annual 4,290
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $71,904 1,236,374
kWh
Electricity Demand $50,344 4,530
kW-mo/yr
Electricity Fees $8,085 -
Natural Gas $15,203 1,865
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $6,963 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,855

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.7224: Reduce space conditioning during non-working hours $2,135 - - - $2,135
-
MMBtu
-
02 2.4322: Use or replace with energy efficient substitutes $785 - $385
6,630
kWh
$400
-
kW-mo/yr
- -
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $115 - $75
1,287
kWh
$40
-
kW-mo/yr
- -
04 2.4231: Reduce the pressure of compressed air to the minimum required $109 - $109
1,882
kWh
- - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,244 $455 $1,244
21,450
kWh
- - -
06 2.7135: Install occupancy sensors $361 $399 $361
6,218
kWh
- - -
07 3.1161: Eliminate/reduce an operation $1,856 $4,320 $(-29.0)
(-492)
kWh
$(-600.0)
-
kW-mo/yr
- $2,485
08 2.7142: Utilize higher efficiency lamps and/or ballasts $35 $85 $17
292
kWh
$18
-
kW-mo/yr
- -
09 2.6211: Conserve energy by efficient use of vending machines $109 $374 $109
1,879
kWh
- - -
10 2.4221: Install compressor air intakes in coolest locations $214 $972 $214
3,689
kWh
- - -
TOTAL RECOMMENDED $6,963 $6,605 $2,485
42,835
kWh
$(-142.0)
-
kW-mo/yr
$2,135
-
MMBtu
$2,485
TOTAL IMPLEMENTED $3,855 $854 $1,680
28,955
kWh
$40
-
kW-mo/yr
$2,135
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs