| Assessment Year | 2012 |
|---|---|
| Principal Product | Cable TV Filters |
| NAICS | 334220: Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing |
| SIC | 3663: Radio and Television Broadcasting and Communications Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 115 |
| Plant Area |
31,000
ft2
|
| Annual Production | 5,000,000
pieces
|
| Production Hrs. Annual | 4,420
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $70,381 | 1,078,218 |
kWh
|
$0.065 |
| Electricity Demand | $50,764 | 3,266 |
kW-mo/yr
|
$15.54 |
| Electricity Fees | $3,079 | - |
|
- |
| Natural Gas | $4,731 | 535 |
MMBtu
|
$8.84 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,107 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $131 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $387 | - |
$387
5,924
kWh
|
- | - | - | |
| 02 | 4.821: Pay bills on time to avoid late fees | $131 | - | - | - | - | $131 | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $533 | $197 |
$143
2,184
kWh
|
$47
-
kW-mo/yr
|
$264 | $79 | |
| 04 | 3.1161: Eliminate/reduce an operation | $1,819 | $1,200 |
$(-28.0)
(-435)
kWh
|
$(-559.0)
-
kW-mo/yr
|
$968 | $1,438 | |
| 05 | 2.7135: Install occupancy sensors | $142 | $218 |
$142
2,179
kWh
|
- | - | - | |
| 06 | 2.6211: Conserve energy by efficient use of vending machines | $222 | $570 |
$222
3,407
kWh
|
- | - | - | |
| 07 | 2.4221: Install compressor air intakes in coolest locations | $430 | $1,454 |
$430
6,581
kWh
|
- | - | - | |
| 08 | 2.4321: Upgrade obsolete equipment | $103 | $440 |
$63
972
kWh
|
$40
-
kW-mo/yr
|
- | - | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,340 | $37,030 |
$4,459
68,289
kWh
|
$2,881
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $11,107 | $41,109 |
$5,818
89,101
kWh
|
$2,409
-
kW-mo/yr
|
$1,232 | $1,648 | ||
| TOTAL IMPLEMENTED | $131 | - | - | - | - | $131 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs