| Assessment Year | 2012 |
|---|---|
| Principal Product | Automotive Tires |
| NAICS | 326211: Tire Manufacturing (except Retreading) |
| SIC | 3011: Tires and Inner Tubes |
| Sales Range | greater than $500 M |
| # of Employees | 1,323 |
| Plant Area |
2,000,000
ft2
|
| Annual Production | 3,500,000
pieces
|
| Production Hrs. Annual | 8,568
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $4,483,736 | 89,674,716 |
kWh
|
$0.050 |
| Electricity Demand | $1,268,784 | 158,598 |
kW-mo/yr
|
$8.00 |
| Electricity Fees | $166,153 | - |
|
- |
| Natural Gas | $2,981,865 | 581,871 |
MMBtu
|
$5.12 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $306,618 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $277,439 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $12,626 | - |
$8,483
169,647
kWh
|
$1,896
-
kW-mo/yr
|
- | - | - | $2,247 | |
| 02 | 2.4314: Use synthetic lubricant | $7,917 | - |
$6,469
129,377
kWh
|
$1,448
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.7124: Make a practice of turning off lights when not needed | $72 | - |
$72
1,440
kWh
|
- | - | - | - | - | |
| 04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $106,547 | $32,436 |
$(-6,769.0)
(-135,374)
kWh
|
$(-1,520.0)
-
kW-mo/yr
|
- |
$114,836
-
MMBtu
|
- | - | |
| 05 | 3.1161: Eliminate/reduce an operation | $12,250 | $11,115 |
$(-325.0)
(-6,506)
kWh
|
$(-2,592.0)
-
kW-mo/yr
|
- | - | $5,720 | $9,447 | |
| 06 | 2.7314: Reduce ventilation air | $3,491 | $4,419 |
$471
9,419
kWh
|
$240
-
kW-mo/yr
|
- |
$2,780
-
MMBtu
|
- | - | |
| 07 | 2.3212: Optimize plant power factor | $162,692 | $408,153 | - | - | $162,692 | - | - | - | |
| 08 | 2.6211: Conserve energy by efficient use of vending machines | $812 | $3,107 |
$812
16,230
kWh
|
- | - | - | - | - | |
| 09 | 2.4321: Upgrade obsolete equipment | $211 | $795 |
$171
3,427
kWh
|
$40
-
kW-mo/yr
|
- | - | - | - | |
| TOTAL RECOMMENDED | $306,618 | $460,025 |
$9,384
187,660
kWh
|
$(-488.0)
-
kW-mo/yr
|
$162,692 |
$117,616
-
MMBtu
|
$5,720 | $11,694 | ||
| TOTAL IMPLEMENTED | $277,439 | $441,384 |
$(-57.0)
(-1,130)
kWh
|
$(-32.0)
-
kW-mo/yr
|
$162,692 |
$114,836
-
MMBtu
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs