Assessment Year | 2010 |
---|---|
Principal Product | Biological Cultures |
NAICS | 325414: Biological Product (except Diagnostic) Manufacturing |
SIC | 2836: Biological Products, Except Diagnostic Substances |
Sales Range | $50 M to 100M |
# of Employees | 70 |
Plant Area |
61,580
ft2
|
Annual Production | 5,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $485,994 | 6,356,640 |
kWh
|
$0.076 |
Other Energy | $410,073 | 32,527 |
MMBtu
|
$12.61 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $82,629 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $70,301 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Energy Savings |
---|---|---|---|---|---|---|
01 | 2.2113: Repair or replace steam traps | $64,500 | $3,122 | - |
$64,500
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,801 | $1,925 |
$5,801
75,336
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $828 | $883 |
$828
10,758
kWh
|
- | |
04 | 2.7135: Install occupancy sensors | $5,195 | $8,204 |
$5,195
67,470
kWh
|
- | |
05 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $6,305 | $11,140 | - |
$6,305
-
MMBtu
|
|
TOTAL RECOMMENDED | $82,629 | $25,274 |
$11,824
153,564
kWh
|
$70,805
-
MMBtu
|
||
TOTAL IMPLEMENTED | $70,301 | $5,047 |
$5,801
75,336
kWh
|
$64,500
-
MMBtu
|