| Assessment Year | 2010 |
|---|---|
| Principal Product | Disposable Thermometer Probe Covers and Light Bulbs |
| NAICS | 334510: Electromedical and Electrotherapeutic Apparatus Manufacturing |
| SIC | 3845: Electromedical and Electrotherapeutic Apparatus |
| Sales Range | $50 M to 100M |
| # of Employees | 350 |
| Plant Area |
159,430
ft2
|
| Annual Production | 390,000,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $354,944 | 4,741,865 |
kWh
|
$0.075 |
| Electricity Demand | $167,723 | 11,585 |
kW-mo/yr
|
$14.48 |
| Electricity Fees | $8,701 | - |
|
- |
| Natural Gas | $76,275 | 10,193 |
MMBtu
|
$7.48 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $245,969 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $162,634 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $81,934 | - |
$51,537
687,162
kWh
|
$23,281
-
kW-mo/yr
|
- |
$7,116
-
MMBtu
|
- | - | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,948 | - |
$2,948
39,312
kWh
|
- | - | - | - | - | - | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $3,753 | $554 |
$3,753
50,045
kWh
|
- | - | - | - | - | - | |
| 04 | 2.7135: Install occupancy sensors | $758 | $447 |
$758
10,101
kWh
|
- | - | - | - | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $540 | $793 |
$197
2,628
kWh
|
$52
-
kW-mo/yr
|
- | - | $291 | - | - | |
| 06 | 3.1191: Change procedures / equipment / operating conditions | $79,942 | $129,646 |
$2,948
39,312
kWh
|
$3,127
-
kW-mo/yr
|
- | - | - | $73,867 | - | |
| 07 | 3.1191: Change procedures / equipment / operating conditions | $71,218 | $132,133 |
$(-18,486.0)
(-246,480)
kWh
|
$(-6,863.0)
-
kW-mo/yr
|
- | - | - | - | $96,567 | |
| 08 | 2.6211: Conserve energy by efficient use of vending machines | $373 | $732 |
$373
4,976
kWh
|
- | - | - | - | - | - | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,680 | $5,928 |
$1,884
25,116
kWh
|
$796
-
kW-mo/yr
|
- | - | - | - | - | |
| 10 | 2.3212: Optimize plant power factor | $1,823 | $8,254 | - | - | $1,823 | - | - | - | - | |
| TOTAL RECOMMENDED | $245,969 | $278,487 |
$45,912
612,172
kWh
|
$20,393
-
kW-mo/yr
|
$1,823 |
$7,116
-
MMBtu
|
$291 | $73,867 | $96,567 | ||
| TOTAL IMPLEMENTED | $162,634 | $130,093 |
$55,243
736,575
kWh
|
$26,408
-
kW-mo/yr
|
- |
$7,116
-
MMBtu
|
- | $73,867 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs