| Assessment Year | 2002 |
|---|---|
| Principal Product | Independent Living Aids |
| NAICS |
n/a
|
| SIC | 3391: |
| Sales Range | $1 M to 5M |
| # of Employees | 19 |
| Plant Area |
35,000
ft2
|
| Annual Production | 245,000
pieces
|
| Production Hrs. Annual | 2,153
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $11,374 | 269,416 |
kWh
|
$0.042 |
| Electricity Demand | $14,510 | 1,395 |
kW-mo/yr
|
$10.40 |
| Electricity Fees | $476 | - |
|
- |
| Natural Gas | $8,976 | 947 |
MMBtu
|
$9.48 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,657 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,407 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,388 | $10,093 |
$886
21,017
kWh
|
$1,220
-
kW-mo/yr
|
- | $13 | $269 | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,542 | $12,107 |
$1,030
24,589
kWh
|
$1,348
-
kW-mo/yr
|
- | - | $164 | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $845 | $1,327 |
$144
3,434
kWh
|
$49
-
kW-mo/yr
|
- | $208 | $444 | |
| 04 | 2.7122: Disconnect ballasts | $162 | $213 |
$68
1,615
kWh
|
$94
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.7135: Install occupancy sensors | $1,250 | $2,401 |
$981
23,333
kWh
|
$269
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.4322: Use or replace with energy efficient substitutes | $610 | $534 |
$14
344
kWh
|
$596
-
kW-mo/yr
|
- | - | - | |
| 07 | 2.8114: Change rate schedules or other changes in utility service | $3,860 | - | - |
$1,959
-
kW-mo/yr
|
$1,901 | - | - | |
| TOTAL RECOMMENDED | $11,657 | $26,675 |
$3,123
74,332
kWh
|
$5,535
-
kW-mo/yr
|
$1,901 | $221 | $877 | ||
| TOTAL IMPLEMENTED | $10,407 | $24,274 |
$2,142
50,999
kWh
|
$5,266
-
kW-mo/yr
|
$1,901 | $221 | $877 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs