Assessment Year | 2010 |
---|---|
Principal Product | Tomato Based Sauces and Salsas |
NAICS | 311421: Fruit and Vegetable Canning |
SIC | 2033: Canned Fruits, Vegetables, Preserves, Jams, and Jellies |
Sales Range | $100 M to 500M |
# of Employees | 450 |
Plant Area |
225,000
ft2
|
Annual Production | 357,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $308,145 | 13,757,400 |
kWh
|
$0.022 |
Electricity Demand | $128,772 | 25,754 |
kW-mo/yr
|
$5.00 |
Natural Gas | $1,508,554 | 221,309 |
MMBtu
|
$6.82 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $650,187 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $647,275 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,574 | - |
$2,574
117,000
kWh
|
- | - | - | - | |
02 | 2.4322: Use or replace with energy efficient substitutes | $1,022 | - |
$422
19,200
kWh
|
$600
-
kW-mo/yr
|
- | - | - | |
03 | 3.4114: Replace city water with recycled water via cooling tower | $595,177 | $272,656 |
$(-15,762.0)
(-716,400)
kWh
|
$(-7,170.0)
-
kW-mo/yr
|
- |
$274,715
-
Tgal
|
$343,394
-
gal
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,178 | $1,225 |
$2,178
99,000
kWh
|
- | - | - | - | |
05 | 2.2414: Use waste heat from hot flue gases to preheat | $29,403 | $27,649 | - | - |
$29,403
-
MMBtu
|
- | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,800 | $1,649 |
$1,800
81,840
kWh
|
- | - | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,943 | $74,298 |
$13,683
621,960
kWh
|
$4,260
-
kW-mo/yr
|
- | - | - | |
08 | 2.6211: Conserve energy by efficient use of vending machines | $90 | $724 |
$90
4,146
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $650,187 | $378,201 |
$4,985
226,746
kWh
|
$(-2,310.0)
-
kW-mo/yr
|
$29,403
-
MMBtu
|
$274,715
-
Tgal
|
$343,394
-
gal
|
||
TOTAL IMPLEMENTED | $647,275 | $375,828 |
$2,673
121,560
kWh
|
$(-2,910.0)
-
kW-mo/yr
|
$29,403
-
MMBtu
|
$274,715
-
Tgal
|
$343,394
-
gal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs