Assessment Year | 2020 |
---|---|
Principal Product | Metal Display Units |
NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
135,000
ft2
|
Annual Production | 300,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $135,104 | 2,641,635 |
kWh
|
$0.051 |
Electricity Demand | $97,456 | 7,022 |
kW-mo/yr
|
$13.88 |
Electricity Fees | $(-4,782.0) | - |
|
- |
TOTAL YEARLY COSTS | $227,778 | |||
RECOMMENDED SAVINGS* | $37,939 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $28,357 | $32,486 |
$21,904
322,122
kWh
|
$6,453
-
kW-mo/yr
|
|
02 | 2.7135: Install occupancy sensors | $1,398 | $3,402 |
$1,398
20,577
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $3,555 | $1,224 |
$2,708
39,818
kWh
|
$848
-
kW-mo/yr
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,628 | - |
$3,525
51,837
kWh
|
$1,103
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $37,939 | $37,112 |
$29,535
434,354
kWh
|
$8,404
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs