Assessment Year 2010
Principal Product Printed promotional note pads and note cubes; sticky note pads and stick
NAICS 322230: Stationery Product Manufacturing
SIC 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 120
Plant Area 119,450
ft2
Annual Production 5,581,754
lb
Production Hrs. Annual 8,736
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $300,752 2,906,579
kWh
Electricity Demand $166,913 10,025
kW-mo/yr
Electricity Fees $13,946 -
Natural Gas $91,754 7,531
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $43,120 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $18,246

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $4,822 - $3,290
31,948
kWh
$1,532
-
kW-mo/yr
- - -
02 2.7122: Disconnect ballasts $2,268 - $1,735
16,848
kWh
$533
-
kW-mo/yr
- - -
03 2.4322: Use or replace with energy efficient substitutes $1,483 - $884
8,580
kWh
$599
-
kW-mo/yr
- - -
04 2.4314: Use synthetic lubricant $190 - $140
1,357
kWh
$50
-
kW-mo/yr
- - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,690 $200 $1,157
11,232
kWh
$533
-
kW-mo/yr
- - -
06 2.7135: Install occupancy sensors $739 $159 $739
7,176
kWh
- - - -
07 2.4221: Install compressor air intakes in coolest locations $1,630 $486 $1,114
10,816
kWh
$516
-
kW-mo/yr
- - -
08 2.7135: Install occupancy sensors $421 $357 $421
4,087
kWh
- - - -
09 2.6211: Conserve energy by efficient use of vending machines $186 $268 $186
1,809
kWh
- - - -
10 2.2437: Recover waste heat from equipment $11,876 $11,749 - - - $11,876
-
MMBtu
-
11 2.7314: Reduce ventilation air $7,633 $10,197 $441
4,282
kWh
$366
-
kW-mo/yr
- $6,826
-
MMBtu
-
12 2.7142: Utilize higher efficiency lamps and/or ballasts $139 $335 $63
613
kWh
$17
-
kW-mo/yr
- - $59
13 3.6193: Install equipment (eg compactor) to reduce disposal costs $8,956 $20,410 - - - - $8,956
14 2.3212: Optimize plant power factor $1,087 $6,486 - - $1,087 - -
TOTAL RECOMMENDED $43,120 $50,647 $10,170
98,748
kWh
$4,146
-
kW-mo/yr
$1,087 $18,702
-
MMBtu
$9,015
TOTAL IMPLEMENTED $18,246 $17,843 $7,293
70,819
kWh
$2,981
-
kW-mo/yr
$1,087 $6,826
-
MMBtu
$59
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs