Assessment Year | 2014 |
---|---|
Principal Product | RV Appliance and HVAC units |
NAICS | 333414: Heating Equipment (except Warm Air Furnaces) Manufacturing |
SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
Sales Range | $50 M to 100M |
# of Employees | 400 |
Plant Area |
300,000
ft2
|
Annual Production | 700,000
pieces
|
Production Hrs. Annual | 4,375
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $221,540 | 3,486,464 |
kWh
|
$0.064 |
Electricity Demand | $164,920 | 14,113 |
kW-mo/yr
|
$11.69 |
Electricity Fees | $13,515 | - |
|
- |
Natural Gas | $224,569 | 42,940 |
MMBtu
|
$5.23 |
LPG | $30,427 | 1,766 |
MMBtu
|
$17.23 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $52,771 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $50,724 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $29,307 | $44,000 | - |
$29,307
-
kW-mo/yr
|
|
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,560 | $12,150 |
$4,406
68,850
kWh
|
$2,154
-
kW-mo/yr
|
|
03 | 2.4239: Eliminate or reduce compressed air usage | $4,677 | $4,500 |
$3,145
49,140
kWh
|
$1,532
-
kW-mo/yr
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,047 | $3,000 |
$1,377
21,513
kWh
|
$670
-
kW-mo/yr
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,989 | $20,000 |
$4,700
73,440
kWh
|
$2,289
-
kW-mo/yr
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,191 | $6,041 |
$2,146
33,525
kWh
|
$1,045
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $52,771 | $89,691 |
$15,774
246,468
kWh
|
$36,997
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $50,724 | $86,691 |
$14,397
224,955
kWh
|
$36,327
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs