Assessment Year | 2009 |
---|---|
Principal Product | Sanitary measurement Equipment |
NAICS | 334513: Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial |
SIC | 3823: Industrial Instruments for Measurement, Display, and Control of Process Variables; and Related Products |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
44,000
ft2
|
Annual Production | 32,000
pieces
|
Production Hrs. Annual | 3,938
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $135,426 | 1,122,060 |
kWh
|
$0.12 |
Electricity Demand | $56,978 | 3,541 |
kW-mo/yr
|
$16.09 |
Electricity Fees | $5,259 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,915 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,034 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,340 | - |
$1,729
14,294
kWh
|
$611
-
kW-mo/yr
|
- | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $198 | - |
$166
1,374
kWh
|
$32
-
kW-mo/yr
|
- | - | |
03 | 2.6218: Turn off equipment when not in use | $5,551 | $260 |
$5,551
45,879
kWh
|
- | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,768 | $182 |
$1,334
11,021
kWh
|
$434
-
kW-mo/yr
|
- | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $715 | $563 |
$490
4,053
kWh
|
$225
-
kW-mo/yr
|
- | - | |
06 | 2.6211: Conserve energy by efficient use of vending machines | $257 | $271 |
$257
2,121
kWh
|
- | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $86 | $72 |
$32
263
kWh
|
$6
-
kW-mo/yr
|
$23 | $25 | |
TOTAL RECOMMENDED | $10,915 | $1,348 |
$9,559
79,005
kWh
|
$1,308
-
kW-mo/yr
|
$23 | $25 | ||
TOTAL IMPLEMENTED | $8,034 | $1,005 |
$7,375
60,953
kWh
|
$659
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs