Assessment Year | 2008 |
---|---|
Principal Product | Ceramic Dinnerware |
NAICS | 327110: Pottery, Ceramics, and Plumbing Fixture Manufacturing |
SIC | 3262: Vitreous China Table and Kitchen Articles |
Sales Range | $10 M to 50M |
# of Employees | 298 |
Plant Area |
646,260
ft2
|
Annual Production | 550,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $523,665 | 12,442,809 |
kWh
|
$0.042 |
Electricity Demand | $264,747 | 24,563 |
kW-mo/yr
|
$10.78 |
Electricity Fees | $57,650 | - |
|
- |
Natural Gas | $2,135,090 | 251,507 |
MMBtu
|
$8.49 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $345,796 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $33,088 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 4.821: Pay bills on time to avoid late fees | $2,751 | - | - | - | - | - | - | $2,751 | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $36,827 | $3,125 |
$30,000
403,573
kWh
|
$6,827
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $16,435 | $2,841 |
$14,273
176,214
kWh
|
$2,162
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,111 | $1,559 |
$11,637
143,664
kWh
|
- | - | - |
$1,474
-
MMBtu
|
- | |
05 | 2.2123: Insulate feedwater tank | $3,428 | $746 | - | - | - |
$3,428
-
MMBtu
|
- | - | |
06 | 2.7135: Install occupancy sensors | $773 | $249 |
$773
9,548
kWh
|
- | - | - | - | - | |
07 | 2.2136: Install / repair insulation on steam lines | $31,841 | $16,299 | - | - | - |
$31,841
-
MMBtu
|
- | - | |
08 | 2.1224: Replace boiler | $199,772 | $200,000 | - | - | - |
$199,772
-
MMBtu
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $33,088 | $52,435 |
$25,000
362,491
kWh
|
$8,088
-
kW-mo/yr
|
- | - | - | - | |
10 | 2.6211: Conserve energy by efficient use of vending machines | $747 | $1,615 |
$747
9,220
kWh
|
- | - | - | - | - | |
11 | 2.3212: Optimize plant power factor | $7,023 | $25,839 | - | - | $7,023 | - | - | - | |
TOTAL RECOMMENDED | $345,796 | $304,708 |
$82,430
1,104,710
kWh
|
$17,077
-
kW-mo/yr
|
$7,023 |
$235,041
-
MMBtu
|
$1,474
-
MMBtu
|
$2,751 | ||
TOTAL IMPLEMENTED | $33,088 | $52,435 |
$25,000
362,491
kWh
|
$8,088
-
kW-mo/yr
|
- | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs