| Assessment Year | 2007 |
|---|---|
| Principal Product | Lightweight Specialty Paper |
| NAICS | 322121: Paper (except Newsprint) Mills |
| SIC | 2621: Paper Mills |
| Sales Range | $10 M to 50M |
| # of Employees | 37 |
| Plant Area |
120,000
ft2
|
| Annual Production | 33,500,000
lb
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,513,757 | 19,354,027 |
kWh
|
$0.078 |
| Electricity Demand | $192,125 | 65,935 |
kW-mo/yr
|
$2.91 |
| Electricity Fees | $59,466 | - |
|
- |
| Natural Gas | $942,182 | 85,060 |
MMBtu
|
$11.08 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $60,824 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $51,998 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $9,856 | - |
$9,375
120,188
kWh
|
$481
-
kW-mo/yr
|
- | |
| 02 | 2.4314: Use synthetic lubricant | $9,114 | - |
$8,671
111,164
kWh
|
$443
-
kW-mo/yr
|
- | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $8,725 | - |
$8,101
103,854
kWh
|
$624
-
kW-mo/yr
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,543 | $901 |
$6,196
79,440
kWh
|
$347
-
kW-mo/yr
|
- | |
| 05 | 2.2135: Repair and eliminate steam leaks | $6,404 | $134 | - | - |
$6,404
-
MMBtu
|
|
| 06 | 2.4221: Install compressor air intakes in coolest locations | $4,230 | $444 |
$4,006
51,360
kWh
|
$224
-
kW-mo/yr
|
- | |
| 07 | 2.2136: Install / repair insulation on steam lines | $3,867 | $788 | - | - |
$3,867
-
MMBtu
|
|
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,800 | $19,800 |
$11,226
143,928
kWh
|
$574
-
kW-mo/yr
|
- | |
| 09 | 2.7135: Install occupancy sensors | $184 | $426 |
$184
2,361
kWh
|
- | - | |
| 10 | 2.6211: Conserve energy by efficient use of vending machines | $101 | $461 |
$101
1,292
kWh
|
- | - | |
| TOTAL RECOMMENDED | $60,824 | $22,954 |
$47,860
613,587
kWh
|
$2,693
-
kW-mo/yr
|
$10,271
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $51,998 | $22,493 |
$39,658
508,441
kWh
|
$2,069
-
kW-mo/yr
|
$10,271
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs