Assessment Year | 2006 |
---|---|
Principal Product | Steel Joist and Decking |
NAICS | 332312: Fabricated Structural Metal Manufacturing |
SIC | 3441: Fabricated Structural Metal |
Sales Range | $100 M to 500M |
# of Employees | 79 |
Plant Area |
500,000
ft2
|
Annual Production | 120,000
ton
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $720,792 | 7,408,800 |
kWh
|
$0.097 |
Electricity Demand | $267,030 | 53,406 |
kW-mo/yr
|
$5.00 |
Electricity Fees | $2,452 | - |
|
- |
Natural Gas | $540,459 | 50,789 |
MMBtu
|
$10.64 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $113,548 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $48,632 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $18,077 | - | - | - |
$18,077
-
MMBtu
|
- | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $8,394 | - |
$7,174
73,960
kWh
|
$1,220
-
kW-mo/yr
|
- | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,730 | - |
$1,435
14,790
kWh
|
$295
-
kW-mo/yr
|
- | - | - | |
04 | 2.4314: Use synthetic lubricant | $1,147 | - |
$952
9,810
kWh
|
$195
-
kW-mo/yr
|
- | - | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $13,094 | $636 |
$11,194
115,400
kWh
|
$1,900
-
kW-mo/yr
|
- | - | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,352 | $1,344 |
$6,367
65,640
kWh
|
$985
-
kW-mo/yr
|
- | - | - | |
07 | 2.6211: Conserve energy by efficient use of vending machines | $438 | $732 |
$408
4,205
kWh
|
$30
-
kW-mo/yr
|
- | - | - | |
08 | 2.7135: Install occupancy sensors | $186 | $428 |
$186
1,915
kWh
|
- | - | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $382 | $912 |
$170
1,752
kWh
|
$10
-
kW-mo/yr
|
- | $32 | $170 | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $39,436 | $104,800 |
$34,151
352,080
kWh
|
$5,285
-
kW-mo/yr
|
- | - | - | |
11 | 2.2492: Use "heat wheel" or other heat exchanger to cross-exchange building exhaust air with make-up air | $23,312 | $73,075 | - | - |
$23,312
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $113,548 | $181,927 |
$62,037
639,552
kWh
|
$9,920
-
kW-mo/yr
|
$41,389
-
MMBtu
|
$32 | $170 | ||
TOTAL IMPLEMENTED | $48,632 | $3,320 |
$26,043
268,477
kWh
|
$4,310
-
kW-mo/yr
|
$18,077
-
MMBtu
|
$32 | $170 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs