Assessment Year | 2006 |
---|---|
Principal Product | Artistic Glass Objects & Stemware |
NAICS | 327212: Other Pressed and Blown Glass and Glassware Manufacturing |
SIC | 3229: Pressed and Blown Glass and Glassware, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
62,395
ft2
|
Annual Production | 128,800
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $87,000 | 971,607 |
kWh
|
$0.090 |
Natural Gas | $1,061,187 | 107,144 |
MMBtu
|
$9.90 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $182,647 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $159,282 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $98,366 | - | - |
$98,366
-
MMBtu
|
- | - | - | |
02 | 2.6241: Reduce temperature of process equipment when on standby | $55,282 | - | - |
$55,282
-
MMBtu
|
- | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,431 | - |
$6,431
71,460
kWh
|
- | - | - | - | |
04 | 2.4314: Use synthetic lubricant | $1,534 | - |
$1,534
17,040
kWh
|
- | - | - | - | |
05 | 2.7122: Disconnect ballasts | $788 | - |
$788
8,760
kWh
|
- | - | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $3,073 | $578 |
$3,073
34,140
kWh
|
- | - | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,210 | $264 |
$1,210
13,440
kWh
|
- | - | - | - | |
08 | 3.4111: Use closed cycle process to minimize waste water production | $3,018 | $1,094 | - | - | - |
$3,018
-
Tgal
|
- | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $477 | $730 |
$236
2,627
kWh
|
- | $74 | - | $167 | |
10 | 2.7135: Install occupancy sensors | $86 | $127 |
$86
960
kWh
|
- | - | - | - | |
11 | 2.6211: Conserve energy by efficient use of vending machines | $378 | $684 |
$378
4,205
kWh
|
- | - | - | - | |
12 | 2.2437: Recover waste heat from equipment | $12,004 | $67,500 |
$12,004
133,375
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $182,647 | $70,977 |
$25,740
286,007
kWh
|
$153,648
-
MMBtu
|
$74 |
$3,018
-
Tgal
|
$167 | ||
TOTAL IMPLEMENTED | $159,282 | $1,699 |
$5,393
59,927
kWh
|
$153,648
-
MMBtu
|
$74 | - | $167 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs