Assessment Year | 2005 |
---|---|
Principal Product | Wine |
NAICS | 312130: Wineries |
SIC | 2084: Wines, Brandy, and Brandy Spirits |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
272,500
ft2
|
Annual Production | 3,000,000
pieces
|
Production Hrs. Annual | 3,060
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $332,264 | 4,301,850 |
kWh
|
$0.077 |
Electricity Demand | $50,380 | 13,235 |
kW-mo/yr
|
$3.81 |
Electricity Fees | $7,027 | - |
|
- |
Natural Gas | $278,244 | 26,228 |
MMBtu
|
$10.61 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,828 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,879 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,070 | - |
$839
10,487
kWh
|
$231
-
kW-mo/yr
|
- | - | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $434 | - |
$359
4,488
kWh
|
$75
-
kW-mo/yr
|
- | - | - | |
03 | 2.8114: Change rate schedules or other changes in utility service | $209 | - | - | - | - | - | $209 | |
04 | 2.2414: Use waste heat from hot flue gases to preheat | $13,581 | $2,035 | - | - | - |
$13,581
-
MMBtu
|
- | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $11,968 | $1,970 |
$8,585
136,274
kWh
|
$3,383
-
kW-mo/yr
|
- | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,737 | $496 |
$1,515
18,941
kWh
|
$222
-
kW-mo/yr
|
- | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $629 | $228 |
$548
6,854
kWh
|
$81
-
kW-mo/yr
|
- | - | - | |
08 | 2.1231: Establish burner maintenance schedule for boilers | $2,257 | $1,220 | - | - | - | - | $2,257 | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $725 | $1,187 |
$410
5,500
kWh
|
$34
-
kW-mo/yr
|
- | - | $281 | |
10 | 2.6211: Conserve energy by efficient use of vending machines | $607 | $1,187 |
$571
7,358
kWh
|
$36
-
kW-mo/yr
|
- | - | - | |
11 | 2.7135: Install occupancy sensors | $91 | $194 |
$91
1,139
kWh
|
- | - | - | - | |
12 | 2.3212: Optimize plant power factor | $1,520 | $13,971 | - | - | $1,520 | - | - | |
TOTAL RECOMMENDED | $34,828 | $22,488 |
$12,918
191,041
kWh
|
$4,062
-
kW-mo/yr
|
$1,520 |
$13,581
-
MMBtu
|
$2,747 | ||
TOTAL IMPLEMENTED | $1,879 | $1,609 |
$1,408
17,981
kWh
|
$190
-
kW-mo/yr
|
- | - | $281 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs